Towards Faster Fetal 3D CINE Cardiac MRI Reconstruction Using Region‐Optimized Virtual Coils ( ROVir )
Open Access
- 22 September 2026
- journal article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 97 (1) , 159-168
Abstract
Purpose: To develop and evaluate, in a feasibility study, a computationally efficient image‐reconstruction pipeline for 3D balanced steady state free precession (bSSFP) CINE fetal cardiac MRI that reduces radial streaking artifacts, increases effective temporal resolution, and improves diagnostic image quality compared with previous work. Methods: Three‐dimensional bSSFP CINE data from 10 volunteers were used. Coil compression was performed using the region‐optimized virtual coils (ROVir) technique and compared with singular value decomposition (SVD) coil compression. For ROVir, the region of interest encompassed the fetal thorax, while the region of interference was positioned over the maternal subcutaneous fat to suppress unwanted signal contributions. Image reconstruction was performed for multiple temporal samplings. Two observers evaluated diagnostic image quality using a visual‐analog scale, and results were analyzed using visual grading characteristics (VGC). Computational efficiency was evaluated using reconstruction runtime and memory usage. Results: Average 3D CINE acquisition time was 5 min, with a reconstruction time of approximately 5 h for both SVD (8channels and 8 phases) and ROVir (3 channels and 16 phases), with approximately equal memory usage. ROVir enabled higher temporal resolution by reducing the channels required. VGC analysis showed a preference for ROVir across all diagnostic criteria (AUC > 0.5), including edge sharpness, perceived image contrast, artifact suppression, papillary muscles, great vessels, and extracardiac diagnostic image quality, with comparable median scores across temporal samplings. Conclusion: ROVir coil compression improved diagnostic quality and reduced reconstruction time. By reducing memory demands, reconstruction with a higher number of cardiac phases was also possible.Keywords
Funding Information
- Region Skåne
- Skånes universitetssjukhus
- Hjärt-Lungfonden (20180510)
- Lund University Medical Faculty Foundation
- Vetenskapsrådet (2019‐05506)
- Siemens Healthineers
This publication has 35 references indexed in Scilit:
- Automatic Respiratory and Bulk Patient Motion Corrected 3D Fetal MRIMagnetic Resonance in Medicine, 2025
- Scanner‐based real‐time automated volumetry reporting of the fetus, amniotic fluid, placenta, and umbilical cord for fetal MRI at 0.55TMagnetic Resonance in Medicine, 2025
- Fetal 3D cardiovascular cine image acquisition using radial sampling and compressed sensingMagnetic Resonance in Medicine, 2022
- Utility of Fetal Cardiovascular Magnetic Resonance for Prenatal Diagnosis of Complex Congenital Heart DefectsJAMA Network Open, 2021
- Region‐optimized virtual (ROVir) coils: Localization and/or suppression of spatial regions using sensor‐domain beamformingMagnetic Resonance in Medicine, 2021
- Fetal whole‐heart 4D imaging using motion‐corrected multi‐planar real‐time MRIMagnetic Resonance in Medicine, 2019
- Estimating absolute‐phase maps using ESPIRiT and virtual conjugate coilsMagnetic Resonance in Medicine, 2016
- Automatic coil selection for streak artifact reduction in radial MRIMagnetic Resonance in Medicine, 2011
- Metric optimized gating for fetal cardiac MRIMagnetic Resonance in Medicine, 2010
- Temporal stability of adaptive 3D radial MRI using multidimensional golden meansMagnetic Resonance in Medicine, 2009