Modeling and measurement of the acoustic lead sensitivity in sagnac fiber sensor arrays
Authors:
- 5 July 2006
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 24 (7) , 2877-2888
Abstract
In this study, a theoretical model of the lead (delay coil and array buses) sensitivity in Sagnac sensor arrays (SSA) for underwater acoustic detection, which induces a spurious pickup and thus a sensor error, is described. In the worst-case scenario, the pickup in a 20-km coil is predicted to be reasonable in deep waters (quietest) (about 17 dB higher than the hydrophone signal) but fairly high (/spl sim/ 52 dB) in shallow waters (noisiest). We show that this pickup can be eliminated for the first few hydrophones in the array by optically folding or double winding the coil, although these approaches are not as effective for the most distant hydrophones in long arrays (/spl ges/ 1 km). These figures are confirmed experimentally in an SSA: Folding a 5-km coil decreased the relative pickup from /spl sim/-42 dB for the first hydrophone and by /spl sim/-8 dB for a hydrophone 1 km down the array. These results concur that for most practical arrays, it is imperative to isolate the coil in an acoustically shielded enclosure, which will reduce the coil pickup to an arbitrarily low level for all hydrophones. Theory and experiment also agree that the pickup in the array buses increases in proportion to the distance along the array. In the worst-case scenario (spherical acoustic wave incident normal to the array), the pickup in a 1-km bus is predicted to be /spl sim/-7 dB in quiet waters and /spl sim/-40 dB in noisy waters. However, in the field, the probability of this event is expected to be extremely low, and these values will be typically at least 15 dB weaker. Nevertheless, in long arrays, the bus pickup must be reduced, which can be achieved by desensitizing the bus fiber and/or pickup subtraction. Combined, these two techniques are expected to make the bus pickup under normal conditions negligible in deep-water applications (/spl sim/-48 dB) and acceptable in noisier shallow-water applications (/spl sim/-15 dB).Keywords
This publication has 17 references indexed in Scilit:
- Pickup suppression in sagnac-based fiber-optic acoustic sensor arrayJournal of Lightwave Technology, 2006
- Demonstration of a folded Sagnac sensor array immune to polarization-induced signal fadingApplied Optics, 2003
- Design, development and construction of fibre-optic bottom mounted array2003
- Seismic fiber optic multiplexed sensors for exploration and reservoir management2000
- Fiber Optic Sensor Systems for Reservoir Fluids Management2000
- A novel fiber-optic sensor array based on the Sagnac interferometerJournal of Lightwave Technology, 1999
- Comparison of fiber-optic Sagnac and Mach-Zehnder interferometers with respect to thermal processes in the fiberJournal of Lightwave Technology, 1995
- Sagnac interferometer for underwater sound detection: noise propertiesOptics Letters, 1989
- Fiber-Optic Acoustic Sensor Based On The Sagnac Interferometer1983
- Pressure desensitization of optical fibersApplied Optics, 1981