A Diagnosis of Heparin-Induced Thrombocytopenia with Combined Clinical and Laboratory Methods in Cardiothoracic Surgical Intensive Care Unit Patients
Authors:
- Anne M. WinklerAWAnne M. Winkler
- Jerrold H. LevyJLJerrold H. Levy
- 1 October 2011
- journal article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 113 (4) , 697-702
Abstract
Against platelet factor 4 (PF4)/heparin complexes and HIT. The sensitivity of readily available antibody immunoassays is high, but specificity is quite low. The use of both a clinical probability score and rapid laboratory immunoassay has been shown to increase specificity, which is of particular importance in the CPB setting. Prompt diagnosis is crucial because cessation of heparin and treatment with alternative anticoagulation can reduce the risk of thromboembolic events. METHODS: We retrospectively reviewed records from cardiothoracic surgical patients whose serum was tested with both the serotonin release assay (SRA) and the PF4/heparin immunoassay from January 2007 through December 2010. We assigned a high, intermediate, or low clinical “4Ts” probability score that quantifies thrombocytopenia, timing of platelet decrease, and thrombotic complications in each patient. We then compared the clinical score and the PF4/heparin immunoassay against the “gold standard” diagnostic test, the SRA. RESULTS: The sensitivity and specificity for PF4/heparin optical density >0.40 were 100% and 26%, respectively. Sensitivity and specificity for the diagnosis of HIT with a combination of PF4/heparin optical density >0.40 and high/intermediate 4Ts score were 100% and 70%, respectively. The negative predictive value was 100% for low 4Ts score. CONCLUSIONS: We demonstrated that the use of the 4Ts clinical score combined with the PF4/heparin immunoassay for HIT diagnosis increases the sensitivity and specificity of HIT testing compared with the PF4/heparin immunoassay alone. Furthermore, with an intermediate 4Ts score and positive PF4/heparin antibody test, a confirmatory platelet activation assay such as the SRA is necessary. Physicians treating patients after cardiothoracic surgery should recognize the need for an antibody test and confirmation with a platelet activation assay with even moderate clinical probability of HIT....Keywords
This publication has 34 references indexed in Scilit:
- Evaluation of a clinical scoring scale to direct early appropriate therapy in heparin-induced thrombocytopeniaJournal of Oncology Pharmacy Practice, 2009
- Thrombotic events in patients with antiplatelet factor 4/heparin antibodiesHeart, 2009
- Formation of anti–platelet factor 4/heparin antibodies after cardiac surgery: Influence of perioperative platelet activation, the inflammatory response, and histocompatibility leukocyte antigen statusThe Journal of Thoracic and Cardiovascular Surgery, 2008
- Anti-heparin/platelet factor 4 antibody optical density values and the confirmatory procedure in the diagnosis of heparin-induced thrombocytopeniaThrombosis and Haemostasis, 2008
- PF4 ENHANCED assay for the diagnosis of heparin-induced thrombocytopenia in complex medical and surgical patients*Critical Care Medicine, 2007
- PF4‐dependent immunoassays and inferential detection of HIT antibodiesJournal of Thrombosis and Haemostasis, 2007
- Changes in platelet count after cardiac surgery can effectively predict the development of pathogenic heparin‐dependent antibodiesBritish Journal of Haematology, 2005
- Diagnostic score for heparin‐induced thrombocytopenia after cardiopulmonary bypassJournal of Thrombosis and Haemostasis, 2004
- The epitope specificity of heparin‐induced thrombocytopeniaBritish Journal of Haematology, 1996
- Heparin-induced thrombocytopenia in open heart surgical patients: Sequelae of late recognitionThe Annals of Thoracic Surgery, 1992