Preventing neuronal damage and inflammationin vivoduring cortical microelectrode implantation through the use of Poloxamer P-188
Authors:
- 21 January 2013
- journal article
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 10 (1) , 016011
Abstract
The aim of this study was to test the efficacy of Poloxamer P188 to reduce cell death and immune response associated with mechanical trauma to cells during implantation of a chronic recording electrode. Ceramic multi-site recording electrodes were implanted bilaterally into 15 adult male Long-Evans rats. One of each pair was randomly assigned to receive a coating of Poloxamer while the other was treated with saline. The extent of neuron loss, and glial cell recruitment were characterized at 2, 4 and 6 weeks post-implantation by stereologic analysis. At 2 and 4 weeks post-implantation, Poloxamer-coated implants showed significantly fewer glial cells and more neurons in the peri-electrode space than controls; however, this significance was lost by 6 weeks. These findings are the first to suggest that Poloxamer has neuroprotective effects in vivo; however, at a fixed loading dose, these effects are limited to approximately 1 month post-implantation.Keywords
This publication has 32 references indexed in Scilit:
- The surface immobilization of the neural adhesion molecule L1 on neural probes and its effect on neuronal density and gliosis at the probe/tissue interfaceBiomaterials, 2011
- Biomaterials for the central nervous systemJournal of The Royal Society Interface, 2008
- Dexamethasone-coated neural probes elicit attenuated inflammatory response and neuronal loss compared to uncoated neural probesBrain Research, 2007
- Bioactive properties of nanostructured porous silicon for enhancing electrode to neuron interfacesJournal of Biomaterials Science, Polymer Edition, 2007
- Nanoscale laminin coating modulates cortical scarring response around implanted silicon microelectrode arraysJournal of Neural Engineering, 2006
- Mechanisms of cell death and neuroprotection by poloxamer 188 after mechanical traumaThe FASEB Journal, 2005
- Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arraysExperimental Neurology, 2005
- Large-scale recording of neuronal ensemblesNature Neuroscience, 2004
- Cryosectioning distortion reduction using tape supportMicroscopy Research and Technique, 2001
- Microglia: a sensor for pathological events in the CNSTrends in Neurosciences, 1996