Reproducibility and Repeatability of Cirrus™ HD-OCT Peripapillary Retinal Nerve Fibre Layer Thickness Measurements in Young Normal Subjects
- 19 January 2012
- journal article
- Published by S. Karger AG in Ophthalmologica
- Vol. 227 (3) , 139-145
Abstract
Purpose: To assess the reproducibility and repeatability of peripapillary retinal nerve fibre layer (RNFL) thickness measurements using a spectral-domain optical coherence tomography (SD-OCT) device in healthy subjects. Methods: In this observational study, 68 young Caucasian healthy volunteers (68 eyes) were subjected to Cirrus™ high-definition (HD) OCT (Zeiss) peripapillary RNFL thickness measurements by two experienced examiners in two different sessions. Average, 4-quadrant and 12-clock-hour sector RNFL thicknesses were analysed. For each option, intra-observer, intrasession repeatability and interobserver, intersession reproducibility were tested. To assess the repeatability of measurements, the Bland and Altman plots were used and the coefficient of repeatability was calculated. Interobserver and intersession reproducibilities were analysed by means of concordance correlation coefficients (CCCs). Results: The sample age ranged from 21 to 39 years (mean 29.09, standard deviation ±5.21). The average RNFL thickness ranged from 90.97 to 91.46 and from 91.34 to 91.78 µm, for the first and the second operator, respectively. The highest repeatability and reproducibility were obtained for average RNFL thickness with coefficients of repeatability of 5.30 and 6.05 µm for the first and the second operator, interoperator CCCs of 0.95 and 0.96 for the first and the second session, and intersession CCCs of 0.96 and 0.97 for the first and the second operator, respectively. Conclusions: Cirrus OCT peripapillary average RNFL thickness measurement in young healthy subjects showed high interoperator and intersession reproducibility. Intrasession repeatability as tested by coefficient of repeatability was next to the device resolution, with very similar results between the two operators. When analysing quadrant and clock hour sector RNFL thickness measurements, both repeatability and reproducibility tend to decrease.Keywords
This publication has 22 references indexed in Scilit:
- Intra and interoperator reproducibility of retinal nerve fibre and macular thickness measurements using Cirrus Fourier-domain OCTActa Ophthalmologica, 2010
- Reproducibility of peripapillary retinal nerve fiber layer thickness with spectral domain cirrus high-definition optical coherence tomography in normal eyesJapanese Journal of Ophthalmology, 2010
- Reproducibility of Retinal Thickness Measurements in Healthy Subjects Using Spectralis Optical Coherence TomographyAmerican Journal of Ophthalmology, 2009
- Three-dimensional Retinal Imaging with High-Speed Ultrahigh-Resolution Optical Coherence TomographyOphthalmology, 2005
- Ophthalmic imaging by spectral optical coherence tomographyAmerican Journal of Ophthalmology, 2004
- Macular and Retinal Nerve Fiber Layer Thickness Measurement Reproducibility Using Optical Coherence Tomography (OCT-3)Journal of Glaucoma, 2004
- Reproducibility of Nerve Fiber Thickness, Macular Thickness, and Optic Nerve Head Measurements Using StratusOCTInvestigative Ophthalmology & Visual Science, 2004
- Retinal nerve fiber layer thickness measured with optical coherence tomography is related to visual function in glaucomatous eyesOphthalmology, 2003
- In vivo human retinal imaging by Fourier domain optical coherence tomographyJournal of Biomedical Optics, 2002
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986