Which pressure to believe? A comparison of direct arterial with indirect blood pressure measurement techniques in the pediatric intensive care unit
Authors:
- Davinia E. WithingtonDWDavinia E. Withington
- Ellen MitchellEMEllen Mitchell
- 1 November 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
- Vol. 12 (6) , e391-e394
Abstract
To determine the accuracy of arterial blood pressure monitoring using 1) direct arterial; 2) automated oscillometric; and 3) sphygmomanometer/Doppler ultrasound measurements in pediatric intensive care patients comparing methods 1) and 2) with 3), the gold standard used to define normal blood pressure. Prospective observational study. Pediatric intensive care unit of a tertiary care pediatric teaching hospital. Forty children (birth to 17 yrs) admitted to the pediatric intensive care unit with various clinical conditions requiring a radial arterial catheter for continuous arterial blood pressure monitoring. None. Each subject had measurements taken every 6 hrs over a 24-hr period. Each set of measurements were: direct arterial blood pressure, indirect blood pressure using the Phillips automated oscillometric device, and indirect blood pressure using the sphygmomanometer and Doppler ultrasound. Analysis used the Bland-Altman plot followed by paired t testing to compare the three different methods. One hundred sixty triads of measurements were analyzed. There were no significant differences between the methods of blood pressure measurement when groups were analyzed based on age. When analyzed by age-specific normo-, hypo-, and hypertensive criteria, arterial blood pressure measurements agree closely with Doppler ultrasound readings, whereas systolic arterial blood pressure measurements were lower than indirect blood pressure using the Phillips automated oscillometric device readings in the hypotensive group (p < .001). In the hypertensive group, the systolic arterial blood pressure values were higher and indirect blood pressure using the Phillips automated oscillometric device readings lower (p < .001) than Doppler ultrasound (p = .03). There was no clinically significant difference between methods in the normotensive group. Diastolic blood pressure measurements were higher by arterial blood pressure in normotensive and hypertensive groups but no different in the hypotensive group. Outside the normotensive range, the automated readings were higher during hypotension and lower during hypertension compared with the arterial and Doppler ultrasound methods. The arterial blood pressure was closer to the gold standard Doppler ultrasound blood pressure in all three blood pressure groups.Keywords
This publication has 9 references indexed in Scilit:
- The Fourth Report on the Diagnosis, Evaluation, and Treatment of High Blood Pressure in Children and AdolescentsPediatrics, 2004
- National health and nutrition examination survey 1999-2000: effect of observer training and protocol standardization on reducing blood pressure measurement errorJournal of Clinical Epidemiology, 2003
- Comparison of Auscultatory and Oscillometric Blood PressuresArchives of Pediatrics & Adolescent Medicine, 2001
- Reliability of the Dinamap Non-invasive Monitor in the Measurement of Blood Pressure of III Asian NewbornsClinical Pediatrics, 1990
- A Comparative Study of the Measurement of Mean Arterial Blood Pressure Using Automatic Oscillometers, Arterial Cannulation and AuscultationAnaesthesia and Intensive Care, 1986
- Is the blood pressure the same in both arms?Clinical Cardiology, 1985
- An Automated Oscillometric Technique for Estimating Mean Arterial Pressure in Critically III NewbornsAnesthesiology, 1981
- Early heart failure as a cause of growth and tissue disorders in children with congenital heart disease.Circulation, 1980
- MEASUREMENT OF BLOOD PRESSURE IN INFANTS AND CHILDREN BY THE DOPPLER ULTRASONIC TECHNIQUEPediatrics, 1971