Helical tomotherapy for single and multiple liver tumours
Open Access
- 24 June 2010
- journal article
- Published by Springer Nature in Radiation Oncology
- Vol. 5 (1) , 58
Abstract
Dosimetric evaluations of single and multiple liver tumours performed using intensity-modulated helical tomotherapy (HT) were quantitatively investigated. Step-and-shoot intensity-modulated radiotherapy (SaS-IMRT) was used as a benchmark. Sixteen patients separated into two groups with primary hepatocellular carcinomas or metastatic liver tumours previously treated using SaS-IMRT were examined and re-planned by HT. The dosimetric indices used included the conformity index (CI) and homogeneity index (HI) for the planned target volume (PTV), max/mean dose, quality index (QI), normal tissue complication probability (NTCP), V(30 Gy), and V(50%) for the specified organs at risk (OARs). The monitor units per fraction (MU/fr) and delivery time were also analysed. For the single tumour group, both planning systems satisfied the required PTV prescription, but no statistical significance was shown by the indexes checking. A shorter delivery time and lower MU/fr value were achieved by the SaS-IMRT. For the group of multiple tumours, the average improvement in CI and HI was 14% and 4% for HT versus SaS-IMRT, respectively. Lower V(50%), V(30 Gy) and QI values were found, indicating a significant dosimetric gain in HT. The NTCP value of the normal liver was 20.27 +/- 13.29% for SaS-IMRT and 2.38 +/- 2.25% for HT, indicating fewer tissue complications following HT. The latter also required a shorter delivery time. Our study suggests dosimetric benefits of HT over SaS-IMRT plans in the case of multiple liver tumours, especially with regards sparing of OARs. No significant dosimetric difference was revealed in the case of single liver tumour, but SaS-IMRT showed better efficiency in terms of MU/fr and delivery time.Keywords
This publication has 53 references indexed in Scilit:
- Integral Dose in Three-dimensional Conformal Radiotherapy, Intensity-modulated Radiotherapy and Helical TomotherapyClinical Oncology, 2009
- Helical tomotherapy for locoregional irradiation including the internal mammary chain in left-sided breast cancer: Dosimetric evaluationRadiotherapy and Oncology, 2009
- DOSE TO NORMAL TISSUES OUTSIDE THE RADIATION THERAPY PATIENT’S TREATED VOLUME: A REVIEW OF DIFFERENT RADIATION THERAPY TECHNIQUESHealth Physics, 2008
- Dosimetric comparisons of helical tomotherapy and step-and-shoot intensity-modulated radiotherapy in nasopharyngeal carcinomaRadiotherapy and Oncology, 2008
- Treatment plan comparison between helical tomotherapy and MLC-based IMRT using radiobiological measuresPhysics in Medicine & Biology, 2007
- Helical tomotherapy dynamic quality assuranceMedical Physics, 2006
- Intensity-modulated radiation therapyCurrent Problems in Cancer, 2004
- Resection of Hepatocellular Carcinoma in Patients Otherwise Eligible for TransplantationAnnals of Surgery, 2003
- Assessment of Hepatic Motion Secondary to Respiration for Computer Assisted InterventionsComputer Aided Surgery, 2002
- Assessment of hepatic motion secondary to respiration for computer assisted interventionsComputer Aided Surgery, 2002