Evaluation of low-volume plasma sampling for the analysis of meropenem in clinical samples
- 3 January 2022
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 414 (6) , 2155-2162
Abstract
Reducing the volume of blood sampled from neonatal or paediatric patients is important to facilitate research in a group that is under-represented in clinical studies. Not all patients have a cannula available for blood sampling, meaning there are real advantages in obtaining a blood microsample by skin prick. In this study, the results obtained from both capillary microsamples (CMS) and a microfluidic (MF)-CMS by skin prick are compared to conventional plasma sampled from an arterial catheter in a clinical bridging study. Six critically ill patients receiving meropenem were included with the incurred sample reanalysis test meeting the acceptance criteria for both CMS (n = 24 samples) and MF-CMS (n = 20 samples). Bland–Altman plots comparing MF-CMS to conventional arterial blood sampling revealed a difference of − 12.7 ± 22.1% (mean ± standard deviation (SD), and comparing CMS to conventional arterial blood sampling a difference of − 3.4 ± 17.0%. At − 12.7%, the bias between MF-CMS and conventional sampling is greater than the bias found with CMS, although within the limit of acceptability for analytical accuracy (that being ± 15%). Samples collected by skin prick and using CMS produced meropenem concentrations that were comparable to those obtained from conventional arterial catheter sampling. CMS samples were found to be stable when stored in the capillary tube for 24 h at 5 °C or for 4 h at room temperature.Keywords
Funding Information
- Royal Brisbane and Women's Hospital Foundation
This publication has 11 references indexed in Scilit:
- Capillary microsampling in mice: effective way to move from sparse sampling to serial sampling in pharmacokinetics profilingXenobiotica, 2019
- Comparison of Toxicokinetic Parameters of a Drug and Two Metabolites Following Traditional and Capillary Microsampling in RatBioanalysis, 2019
- Analysis of capillary microsamples obtained from a skin-prick to measure vancomycin concentrations as a valid alternative to conventional sampling: A bridging studyJournal of Pharmaceutical and Biomedical Analysis, 2019
- Evaluation of the Capitainer-B Microfluidic Device as a New Hematocrit-Independent Alternative for Dried Blood Spot CollectionAnalytical Chemistry, 2018
- Impact of β-lactam antibiotic therapeutic drug monitoring on dose adjustments in critically ill patients undergoing continuous renal replacement therapyInternational Journal of Antimicrobial Agents, 2017
- Invasiveness of pharmacokinetic studies in children: a systematic reviewBMJ Open, 2016
- EBF: Reflection on Bioanalytical Assay Requirements Used to Support Liquid MicrosamplingBioanalysis, 2014
- Volumetric Absorptive Microsampling: A Dried Sample Collection Technique for Quantitative BioanalysisAnalytical Chemistry, 2014
- An international, multicentre survey of -lactam antibiotic therapeutic drug monitoring practice in intensive care unitsJournal of Antimicrobial Chemotherapy, 2014
- Capillary Microsampling and Analysis of 4-µL Blood, Plasma and Serum Samples to Determine Human α-Synuclein Elimination Rate in MiceBioanalysis, 2013