Evaluation of anastomosis quality with intraoperative transit time flowmeter in minimally invasive multi-vessel coronary artery bypass grafting via left anterior mini-thoracotomy
Authors:
Open Access
- 1 January 2023
- journal article
- research article
- Published by Galenos Yayinevi in Turkish Journal of Thoracic and Cardiovascular Surgery
- Vol. 31 (1) , 56-62
Abstract
Background: In this study, we aimed to describe our intraoperative transit-time flow measurement results as an integral component of the operation and evaluate the graft patency and anastomosis quality in patients who underwent minimally invasive multi-vessel coronary artery bypass grafting via mini-thoracotomy. Methods: Between May 2020 and September 2021, a total of 45 consecutive patients (32 males, 13 females; mean age: 51.2±8.6 years; range, 41 to 72 years) who underwent minimally invasive multi-vessel coronary artery bypass grafting via left anterior mini-thoracotomy were retrospectively analyzed. We used the technique of intraoperative transit-time flowmetry in all patients. The patients were operated under cardiopulmonary bypass. A saphenous vein graft was used in all anastomoses, except for the left internal thoracic artery. Results: The mean left internal mammary artery flow rate was 36.2±14.1 mL/min, mean flow rate of the diagonal grafts was 48.2±13.1 mL/min, mean flow rate of the circumflex grafts was 41.2±21.1 mL/min, and mean flow rate of the right coronary artery grafts was 52.2±11.3 mL/min. Wave patterns and flow parameters of all grafts were normal in the intraoperative measurements, since the pulsatility index values in all anastomoses were within normal limits. The operation was completed after anastomotic openings and graft patency were ensured. Conclusion: The use of an intraoperative flowmeter to show the graft patency and anastomosis quality gives confidence both to the surgeon and the patient. In multi-vessel coronary artery bypass grafting via mini-thoracotomy, anastomosis quality can be evaluated well with this technique.Keywords
This publication has 12 references indexed in Scilit:
- Comparison of postoperative outcomes between robotic mitral valve replacement and conventional mitral valve replacementJournal of Cardiac Surgery, 2021
- Intraoperative transit-time flow measurement and high-frequency ultrasound assessment in coronary artery bypass graftingThe Journal of Thoracic and Cardiovascular Surgery, 2020
- Redo robotic cardiac surgery and concomitant cesarean section in a pregnant patient with dextrocardia and situs inversus totalisJournal of Cardiac Surgery, 2019
- 2018 ESC/EACTS Guidelines on myocardial revascularizationEuroIntervention, 2019
- 2018 ESC/EACTS Guidelines on myocardial revascularizationEuropean Journal of Cardio-Thoracic Surgery, 2018
- Relationship of Intraoperative Transit Time Flowmetry Findings to Angiographic Graft Patency at Follow-UpThe Annals of Thoracic Surgery, 2016
- Transit-time flow predicts outcomes in coronary artery bypass graft patients: a series of 1000 consecutive arterial grafts☆European Journal of Cardio-Thoracic Surgery, 2010
- The effects of on-pump and off-pump coronary artery bypass grafting on intraoperative graft flow in arterial and venous conduits defined by a flow/pressure ratioThe Journal of Thoracic and Cardiovascular Surgery, 2008
- Predictive value of intraoperative transit-time flow measurement for short-term graft patency in coronary surgeryThe Journal of Thoracic and Cardiovascular Surgery, 2006
- An evaluation of the intraoperative transit time measurements of coronary bypass flowEuropean Journal of Cardio-Thoracic Surgery, 2001