Pre-Discharge Duplex Ultrasound Scans Detect Endoleaks Not Seen on Completion Angiography After Endovascular Aneurysm Repair
- 1 June 2010
- journal article
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 17 (3) , 349-353
Abstract
Purpose: To determine whether a pre-discharge duplex ultrasound scan detects early endoleaks that would not otherwise have been identified. Methods: A retrospective review was conducted of all patients undergoing elective infrarenal endovascular aneurysm repair (EVAR) at our center. These patients underwent intraoperative completion angiography, had a duplex ultrasound scan prior to hospital discharge, and were followed at 1, 3, and 6 months and at 6-month intervals thereafter. The outcome of any patients found to have an endoleak on a pre-discharge scan was studied. Results: There were 52 EVAR patients (50 men; mean age 76 years, range 61–87) with endoleak on the pre-discharge duplex: 17 (2.8%) type I, 28 (4.6%) type II, and 8 (1.3%) type III. Of these, only 7 of the type I and 2 of the type II leaks had been detected on completion angiography. Among the patients with type I endoleaks, 5 had resolution of the leak, 10 required further endovascular interventions, and 2 had open repair (1 died of aneurysm rupture). Two patients with failed endovascular repairs of the leak also had open repair. Fifteen of the 28 type II endoleaks resolved, 4 were treated with endovascular procedures, 1 had open repair, 7 are being observed, and 1 was lost to follow-up. Six of the 8 type III leaks resolved, 1 required open repair for an enlarging sac, and 1 is being observed. Conclusion: Despite routine completion angiography, new endoleaks may be identified postoperatively, which suggests that more rigorous imaging at the point of completion angiography is required.Keywords
This publication has 18 references indexed in Scilit:
- Persistent type 2 endoleak after endovascular repair of abdominal aortic aneurysm is associated with adverse late outcomesJournal of Vascular Surgery, 2007
- Patient fitness and survival after abdominal aortic aneurysm repair in patients from the UK EVAR trialsBritish Journal of Surgery, 2007
- Clinical Significance of Type II Endoleak after Endovascular Repair of Abdominal Aortic AneurysmAnnals of Vascular Surgery, 2006
- Systematic review of recent evidence for the safety and efficacy of elective endovascular repair in the management of infrarenal abdominal aortic aneurysmBritish Journal of Surgery, 2005
- Endovascular aneurysm repair and outcome in patients unfit for open repair of abdominal aortic aneurysm (EVAR trial 2): randomised controlled trialThe Lancet, 2005
- Endovascular aneurysm repair versus open repair in patients with abdominal aortic aneurysm (EVAR trial 1): randomised controlled trialThe Lancet, 2005
- A Randomized Trial Comparing Conventional and Endovascular Repair of Abdominal Aortic AneurysmsNew England Journal of Medicine, 2004
- Type II endoleak after endovascular abdominal aortic aneurysm repair: a conservative approach with selective intervention is safe and cost-effectiveJournal of Vascular Surgery, 2004
- An Update on the Important Findings from the EUROSTAR EVAR RegistryVascular, 2003
- Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experienceJournal of Vascular Surgery, 2000