Overview of Intracameral Drug Delivery Systems in Glaucoma
Authors:
- Kelvin ShiKSKelvin Shi
- Yazan AbubakerYAYazan Abubaker
- Mary LangMLMary Lang
- Raziye Dönmez GünRGRaziye Dönmez Gün
- Raphael BanoubRBRaphael Banoub
- Abhimanyu AhujaAAAbhimanyu Ahuja
- Isabella WagnerIWIsabella Wagner
- Syril DorairajSDSyril Dorairaj
Open Access
- 1 February 2026
- journal article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-11
Abstract
Glaucoma is the leading cause of irreversible blindness worldwide, and intraocular pressure (IOP) remains the only proven modifiable risk factor for slowing disease progression. Although topical medications are the standard first-line therapy, their effectiveness is limited by poor adherence and low ocular bioavailability. These limitations have prompted the development of non-topical drug delivery systems (DDSs) that aim to provide consistent long-term IOP control without reliance on patient-administered drops. Among these approaches, intracameral DDSs have received increasing attention for their ability to deliver medication directly to the anterior chamber. This review aims to provide clinicians with an overview of the design, clinical performance, and key considerations of the two FDA-approved intracameral implants, Durysta® (BimSR) and iDose® TR (iDose), as well as investigational devices including ENV515, OTX-TIC, and PA5108. Currently, clinical trials indicate that these devices can achieve sustained reductions in IOP with efficacy comparable to topical prostaglandins (PGA), and real-world studies similarly report reductions in both IOP and medication burden. However, several limitations remain, including concerns about corneal endothelial cell loss (CECL), variability in treatment response among patients with more advanced disease, and the limited availability of long-term safety and durability data. In addition, randomized comparative studies evaluating intracameral DDSs against other glaucoma interventions, such as minimally invasive glaucoma surgery (MIGS), are scarce. Intracameral DDSs represent a developing area within glaucoma management, and further evidence is needed to clarify their long-term safety and their appropriate role within personalized treatment strategies.Keywords
This publication has 35 references indexed in Scilit:
- Drug delivery systems in glaucoma – Current innovations and future perspectivesAsia-Pacific Journal of Ophthalmology, 2025
- Prospective 18-Month Study of Bimatoprost Intracameral Implant in Patients with Open-Angle Glaucoma or Ocular Hypertension in US Clinical PracticeDrugs, 2025
- Phase 3, Randomized, Comparison Study of Intracameral Bimatoprost Implant 10 µg and Selective Laser TrabeculoplastyAmerican Journal of Ophthalmology, 2025
- Long-Term Safety and Efficacy Evaluation of Travoprost Intracameral Implant Based on Pooled Analyses from Two Phase III TrialsDrugs, 2024
- Sustained Release Therapies with the Prostaglandin Analogues Intracameral ImplantsOphthalmology and Therapy, 2024
- Efficacy and Safety of the Travoprost Intraocular Implant in Reducing Topical IOP-Lowering Medication Burden in Patients with Open-Angle Glaucoma or Ocular HypertensionDrugs, 2023
- Single Administration of Intracameral Bimatoprost Implant 10 µg in Patients with Open-Angle Glaucoma or Ocular HypertensionOphthalmology and Therapy, 2022
- Phase 3, Randomized, 20-Month Study of the Efficacy and Safety of Bimatoprost Implant in Patients with Open-Angle Glaucoma and Ocular Hypertension (ARTEMIS 2)Drugs, 2021
- 24-Month Phase I/II Clinical Trial of Bimatoprost Sustained-Release Implant (Bimatoprost SR) in Glaucoma PatientsDrugs, 2019
- The Ocular Hypertension Treatment StudyArchives of Ophthalmology (1950), 2002