Flexion and Extension Gap Balancing in Revision Total Knee Arthroplasty
Authors:
- William M MihalkoWMWilliam M Mihalko
- Kenneth A KrackowKKKenneth A Krackow
- 1 May 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 446, 121-126
Abstract
Revision total knee arthroplasty presents a unique set of problems when attempting to balance flexion and extension gaps. Loss of soft tissue support and established deformity can make balancing difficult. One needs to balance the flexion and extension gap heights as well as medial and lateral symmetry, which may not always be attainable. We used a set of stepwise techniques to reestablish the joint line in extension using femoral augments, and then balanced the flexion gap using different sized femoral components. We retrospectively analyzed 45 patients who had revision total knee replacement with an average of 4 years followup. These patients had a mean flexion of 105 degrees and none had signs of instability in flexion or extension or on clinical exam. Despite the complex nature of revision knee arthroplasty, cases utilizing an algorithm to balance the extension and flexion gaps, with increased implant constraint when necessary, can aid in obtaining a good outcome. Therapeutic study, level IV (case series). See Guidelines for Authors for a complete description of levels of evidence.Keywords
This publication has 20 references indexed in Scilit:
- TOTAL KNEE ARTHROPLASTY FOR SEVERE VALGUS DEFORMITYJournal of Bone and Joint Surgery, 2004
- Ligament Advancement Techniques in Primary and Revision Total Knee ArthroplastyTechniques in Knee Surgery, 2003
- Effect of Selective Lateral Ligament Release on Stability in Knee ArthroplastyClinical Orthopaedics and Related Research, 2002
- Revision Total Knee Replacement Ligament Balancing for DeformityClinical Orthopaedics and Related Research, 2002
- Does implant selection affect outcome of revision knee arthroplasty?The Journal of Arthroplasty, 2001
- The Use of Structural Allograft for Uncontained Defects in Revision Total Knee ArthroplastyJournal of Bone and Joint Surgery, 2001
- The use of a modular rotating hinge component in salvage revision total knee arthroplastyThe Journal of Arthroplasty, 2000
- Anatomic and biomechanical aspects of pie crusting posterolateral structures for valgus deformity correction in total knee arthroplastyThe Journal of Arthroplasty, 2000
- Results of Total Knee Arthroplasty With Medial Epicondylar Osteotomy to Correct Varus DeformityClinical Orthopaedics and Related Research, 1999
- Revision total knee arthroplasty with use of modular components with stems inserted without cement.Journal of Bone and Joint Surgery, 1995