Drop sizes and population balance model for a Karr column
- 24 August 2021
- journal article
- research article
- Published by Wiley in AIChE Journal
- Vol. 68 (1) , e17413
Abstract
Drop sizes were investigated and measured in a Karr column. A stagewise population balance model was presented considering drop breakage and coalescence. The same breakage mechanisms observed in the single drop study were also found in column. The breakage probability model was selected by comparing the model from single drop study and the widely used models. Model parameters were calculated based on a two‐step optimization method. The results showed that the drop sizes decreased with an increase in reciprocating intensity, but changed slightly with phase velocities. The predicted drop sizes were compared to the experimental data in previous studies and good agreement was achieved. Finally, the population balance model along with some existing correlations were compared with the experimental data. It was found that the population balance model and correlations with the low agitation term provided better predictions of drop sizes in the Karr column. Transport Phenomena and Fluid Mechanics: Karr column, drop size distribution, population balance model, parameter optimization.Keywords
Funding Information
- University of Melbourne
- Tsinghua University
This publication has 49 references indexed in Scilit:
- Estimation of Coalescence Parameters in an Agitated Extraction Column Using a Hybrid AlgorithmChemical Engineering & Technology, 2011
- Performance and Scale-up of Karr Reciprocating Plate Extraction ColumnsIndustrial & Engineering Chemistry Research, 2008
- LLECMOD: A Windows-based program for hydrodynamics simulation of liquid–liquid extraction columnsChemical Engineering and Processing - Process Intensification, 2006
- Droplet population balance modelling—hydrodynamics and mass transferChemical Engineering Science, 2006
- A correlation for drop size and slip velocity in reciprocating plate columnBioprocess and Biosystems Engineering, 1998
- A simplified hydrodynamic model for a pulsed sieve-plate extraction columnChemical Engineering and Processing - Process Intensification, 1997
- Single drop experiments with liquid test systems: A way of comparing two types of mechanically agitated extraction columnsThe Chemical Engineering Journal, 1991
- Single drop break-up in a Kühni columnThe Chemical Engineering Journal, 1990
- Break-up of a drop in a stirred tankChemical Engineering and Processing - Process Intensification, 1988
- Effect of mass transfer on drop size in a Karr columnChemical Engineering and Processing - Process Intensification, 1986