Ultrasonography for confirmation of gastric tube placement

Authors:

Abstract
Gastric tubes are commonly used for the administration of drugs and tube feeding for people who are unable to swallow. Feeding via a tube misplaced in the trachea can result in severe pneumonia. Therefore, the confirmation of tube placement in the stomach after tube insertion is important. Recent studies have reported that ultrasonography provides good diagnostic accuracy estimates in the confirmation of appropriate tube placement. Hence, ultrasound could provide a promising alternative to X-rays in the confirmation of tube placement, especially in settings where X-ray facilities are unavailable or difficult to access. To assess the diagnostic accuracy of ultrasound for gastric tube placement confirmation. We searched the Cochrane Library (2016, Issue 3), MEDLINE (to March 2016), Embase (to March 2016), National Institute for Health Research (NIHR) PROSPERO Register (to May 2016), Aggressive Research Intelligence Facility Databases (to May 2016), ClinicalTrials.gov (to May 2016), ISRCTN registry (May 2016), World Health Organization International Clinical Trials Registry Platform (to May 2016) and reference lists of articles, and contacted study authors. We included studies that evaluated the diagnostic accuracy of naso- and orogastric tube placement confirmed by ultrasound visualization using X-ray visualization as the reference standard. We included cross-sectional studies, and case-control studies. We excluded case series or case reports. Studies were excluded if X-ray visualization was not the reference standard or if the tube being placed was a gastrostomy or enteric tube. Two review authors independently assessed the risk of bias and extracted data from each of the included studies. We contacted authors of the included studies to obtain missing data. We identified 10 studies (545 participants and 560 tube insertions) which met our inclusion criteria. No study was assigned low risk of bias or low concern in every QUADAS-2 domain. We judged only three (30%) studies to have low risk of bias in the participant selection domain because they performed ultrasound after they confirmed correct position by other methods. Few data (43 participants) were available for misplacement detection (specificity) due to the low incidence of misplacement. We did not perform a meta-analysis because of considerable heterogeneity of the index test such as the difference of echo window, the combination of ultrasound with other confirmation methods (e.g. saline flush visualization by ultrasound) and ultrasound during the insertion of the tube. For all settings, sensitivity estimates for individual studies ranged from 0.50 to 1.00 and specificity estimates from 0.17 to 1.00. For settings where X-ray was not readily available and participants underwent gastric tube insertion for drainage (four studies, 305 participants), sensitivity estimates of ultrasound in combination with other confirmatory tests ranged from 0.86 to 0.98 and specificity estimates of 1.00 with wide confidence intervals. For the studies using ultrasound alone (four studies, 314 participants), sensitivity estimates ranged from 0.91 to 0.98 and specificity estimates from 0.67 to 1.00. Of 10 studies that assessed the diagnostic accuracy of gastric tube placement, few studies had a low risk of bias. Based on limited evidence, ultrasound does not have sufficient accuracy as a single test to confirm gastric tube placement. However, in settings where X-ray is not readily available, ultrasound may be useful to detect misplaced gastric tubes. Larger studies are needed to determine the possibility of adverse events when ultrasound is used to confirm tube placement. Les ultrasons pour confirmer le positionnement d'une sonde gastrique Les sondes gastriques sont couramment utilisées pour administrer des médicaments ou une alimentation entérale aux personnes ne pouvant plus avaler. Une alimentation au travers d'un tube placé dans la trachée peut entraîner une pneumonie grave. Par conséquent, confirmer le placement de la sonde dans l'estomac après son insertion est important. De récentes études ont rapporté que les ultrasons fournissent une bonne précision diagnostique pour confirmer que le placement de la sonde est approprié. Ainsi, les ultrasons pourraient fournir une alternative prometteuse à la radiographie pulmonaire pour confirmer le placement de la sonde, en particulier dans des contextes où des services de radiographie ne sont pas disponibles ou difficiles d'accès. Évaluer la précision diagnostique des ultrasons pour confirmer la mise en place des sondes gastriques. Nous avons consulté la Bibliothèque Cochrane (2016, numéro 3), MEDLINE (jusqu'en mars 2016), Embase (jusqu'en mars 2016), le registre PROSPERO du National Institute for Health Research (NIHR) (jusqu'en mai 2016), les bases de données de l'Aggressive Research Intelligence Facility (jusqu'en mai 2016), ClinicalTrials.gov (jusqu'en mai 2016), le registre ISRCTN (mai 2016), l'ICTRP de l'OMS (jusqu'en mai 2016), les références bibliographiques des articles et nous avons contacté les auteurs des études. Nous avons inclus les études ayant évalué la précision diagnostic du positionnement de sondes naso-gastriques ou oro-gastriques confirmée par visualisation d'ultrasons avec la visualisation de radiographies comme référence. Nous avons inclus les études transversales et les études cas-témoins. Nous avons exclus les séries de cas ou les rapports de cas. Les études ont été exclues lorsque la visualisation de radiographies n'était pas la norme de référence ou si la sonde placée était une sonde de gastrostomie ou une sonde entérique. Deux auteurs de la revue ont indépendamment évalué le risque de biais et extrait les données de chacune des...

This publication has 36 references indexed in Scilit: