Performance of very thin Gd2SiO5scintillator bars for the LHCf experiment
Authors:
- 1 January 2013
- journal article
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 8 (01) , T01007
Abstract
To increase the radiation resistivity of the calorimeter, the LHCf group plans to replace its plastic scintillator with Gd2SiO5 (GSO) scintillator. In this report, we present the basic performance of very thin GSO scintillator bars that will replace the scintillating fibers employed as the position sensitive part of the current LHCf detector. The size of a bar is 1 mm × 1 mm × 40 mm. White acrylic paint was painted on one group of GSO bars and a second group was unpainted. After observing a clear peak of cosmic ray muons corresponding to 3 to 4 photoelectrons, a quantitative test was performed by using a 290 MeV/n carbon beam at HIMAC in Japan. The non-painted bars have less position dependence of light collection efficiency (effective attenuation length is about 140 mm) and less piece-to-piece variation. The unpainted bars show about 8% cross talk between adjacent bars which is larger than the painted ones. However, for estimating the center of a cascade shower inside the calorimeter, uniformity of light collection is more important than cross talk, so we have decided to use non-painted bars in the LHCf detector. A simulation of a 100 GeV electron injected in the center of the detector shows that position dependence and cross talk cause only a 0.04 mm shift of the shower centroid without any correction applied. This shows that these effects are relatively small compared to the uncertainty of the beam center position which was 1 mm for the LHCf experiments already performed at √s =7 TeV.Keywords
This publication has 8 references indexed in Scilit:
- Measurement of zero degree inclusive photon energy spectra for proton–proton collisions at LHCPhysics Letters B, 2012
- Measurement of zero degree single photon energy spectra for proton–proton collisions at LHCPhysics Letters B, 2011
- Study of radiation hardness of Gd2SiO5scintillator for heavy ion beamJournal of Instrumentation, 2011
- The construction and testing of the silicon position sensitive modules for the LHCf experiment at CERNJournal of Instrumentation, 2010
- Performance of the Arm#1 Detector for LHCf ExperimentJournal of the Physical Society of Japan, 2009
- The LHCf detector at the CERN Large Hadron ColliderJournal of Instrumentation, 2008
- Applications of cerium-doped gadolinium silicate Gd2SiO5:Ce scintillator to calorimeters in high-radiation environmentNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998
- Cerium-activated Gd2SiO5 single crystal scintillatorApplied Physics Letters, 1983