An experimental study on the influence of scatter and beam hardening in x-ray CT for dimensional metrology
Authors:
- 1 December 2015
- journal article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 27 (1) , 015007
Abstract
Scattered radiation and beam hardening introduce artefacts that degrade the quality of data in x-ray computed tomography (CT). It is unclear how these artefacts influence dimensional measurements evaluated from CT data. Understanding and quantifying the influence of these artefacts on dimensional measurements is required to evaluate the uncertainty of CT-based dimensional measurements. In this work the influence of scatter and beam hardening on dimensional measurements is investigated using the beam stop array scatter correction method and spectrum pre-filtration for the measurement of an object with internal and external cylindrical dimensional features. Scatter and beam hardening are found to influence dimensional measurements when evaluated using the ISO50 surface determination method. On the other hand, a gradient-based surface determination method is found to be robust to the influence of artefacts and leads to more accurate dimensional measurements than those evaluated using the ISO50 method. In addition to these observations the GUM method for evaluating standard measurement uncertainties is applied and the standard measurement uncertainty due to scatter and beam hardening is estimated.Keywords
This publication has 27 references indexed in Scilit:
- Towards geometrical calibration of x-ray computed tomography systems—a reviewMeasurement Science and Technology, 2015
- Current state of standardization in the field of dimensional computed tomographyMeasurement Science and Technology, 2014
- Industrial applications of computed tomographyCIRP Annals, 2014
- Physical characterization and performance evaluation of an x-ray micro-computed tomography system for dimensional metrology applicationsMeasurement Science and Technology, 2012
- Analysis of the effect of cone-beam geometry and test object configuration on the measurement accuracy of a computed tomography scanner used for dimensional measurementMeasurement Science and Technology, 2011
- Comparison between beam-stop and beam-hole array scatter correction techniques for industrial X-ray cone-beam CTNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2011
- Computed tomography for dimensional metrologyCIRP Annals, 2011
- Reducing non-linear artifacts of multi-material objects in industrial 3D computed tomographyNDT & E International, 2008
- Image blur in a flat-panel detector due to Compton scattering at its internal mountingsMeasurement Science and Technology, 2007
- The effects of scatter in x‐ray computed tomographyMedical Physics, 1982