Computer-Aided Volumetric Comparison of Reconstructed Orbits for Blow-Out Fractures With Nonpreformed Versus 3-Dimensionally Preformed Titanium Mesh Plates
Authors:
- Paolo ScolozziPSPaolo Scolozzi
- Armen MomjianAMArmen Momjian
- Joris HeubergerJHJoris Heuberger
- 1 January 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 34 (1) , 98-104
Abstract
To compare and evaluate, using computer-aided volumetric measurements, the accuracy and reliability of nonpreformed mesh plates (NPMPs) versus 3-dimensionally preformed titanium mesh plates (PMPs) in posttraumatic orbital volume restoration. Facial coronal computed tomographic scan slices from 20 patients (10 in the NPMP and 10 in the PMP group) were used to measure bony orbital volume using OsiriX Medical Image software (version 3.3.2, www.osirix-viewer.com). The procedure was performed on both orbits; thereafter, the volume of the contralateral health orbit was used as a control for comparison in the 2 groups of patients. The difference in orbital volume between the 2 groups and between the reconstructed versus uninjured side in both groups have been statistically correlated. The mean orbital volume between the reconstructed (19.215 mL in NPMP and 21.791 mL in PMP) and the contralateral uninjured side (18.955 mL in NPMP and 21.710 mL in PMP) was not statistically significant (P > 0.05). The mean orbital volumes of the reconstructed orbits were 19.215 mL in the NPMP and 21.791 mL in the PMP group, with no statistically significant difference (P > 0.05). The volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with an accuracy of a maximum of 1.85 mL in the NPMP group and 2.5 mL in the PMP group. The current study demonstrated that there were no significant differences in the orbital volume restoration using either technique. In fact, both techniques allow for close reproduction of natural orbital volume and shape, and its use in posttraumatic orbital wall reconstruction was successful.Keywords
This publication has 31 references indexed in Scilit:
- Individual preformed titanium meshes for orbital fracturesOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2006
- OsiriX: An Open-Source Software for Navigating in Multidimensional DICOM ImagesJournal of Digital Imaging, 2004
- Dimensions and volumes of the orbit and orbital fat in posttraumatic enophthalmosDentomaxillofacial Radiology, 2000
- Prediction of Late Enophthalmos by Volumetric Analysis of Orbital FracturesOphthalmic Plastic & Reconstructive Surgery, 1998
- Prediction of enophthalmos by computed tomography after 'blow out' orbital fracture.British Journal of Ophthalmology, 1994
- Bone-Graft Reconstruction of the Monkey Orbital Floor with Iliac Grafts and Titanium Mesh PlatesPlastic and Reconstructive Surgery, 1993
- Orbital volume measurement in the management of pure blowout fractures of the orbital floor.British Journal of Ophthalmology, 1993
- Titanium mesh in orbital wall reconstructionInternational Journal of Oral and Maxillofacial Surgery, 1992
- Reconstruction of Internal Orbital Fractures with Vitallium MeshPlastic and Reconstructive Surgery, 1991
- Volume measurements of normal orbital structures by computed tomographic analysisAmerican Journal of Roentgenology, 1985