Lateral Decubitus Dynamic CT Myelography with Real-Time Bolus Tracking (dCTM-BT) for Evaluation of CSF-Venous Fistulas: Diagnostic Yield Stratified by Brain Imaging Findings
Authors:
- Thien J. HuynhTHThien J. Huynh
- Donna ParizadehDPDonna Parizadeh
- Ahmed K. AhmedAAAhmed K. Ahmed
- Christopher T. GandiaCGChristopher T. Gandia
- Hal C. DavisonHDHal C. Davison
- John V. MurrayJMJohn V. Murray
- Ian T. MarkIMIan T. Mark
- Ajay A. MadhavanAMAjay A. Madhavan
- Darya ShlapakDSDarya Shlapak
- Todd D. RozenTRTodd D. Rozen
- Waleed BrinjikjiWBWaleed Brinjikji
- Prasanna VibhutePVPrasanna Vibhute
Open Access
- 28 December 2023
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 45 (1) , 105-112
Abstract
BACKGROUND AND PURPOSE: CSF-venous fistulas (CVFs) associated with spontaneous intracranial hypotension (SIH) may have a transient appearance, relative to contrast arrival, which may influence the diagnostic performance of lateral decubitus CT myelography (CTM). We developed a dynamic CTM protocol using real-time bolus-tracking (dCTM-BT) to improve the temporal resolution and standardize the timing of CTM acquisitions post-intrathecal contrast administration. The purpose of our study was to evaluate the feasibility of the dCTM-BT technique and evaluate its diagnostic yield for CVF detection, stratified by brain MRI SIH findings. MATERIALS AND METHODS: Patients with suspected SIH without extradural fluid collection on spine MRI who underwent dCTM-BT were retrospectively reviewed. CT bolus monitoring was performed at the upper thoracic level. Following the visualization of dense intrathecal contrast, at least 3 CTM acquisitions of the spine were obtained and reviewed by 2 neuroradiologists. The Bern SIH score was calculated on the brain MRI. The diagnostic yield for CVF detection was evaluated, stratified by Bern score categories and a receiver operating characteristic (ROC) analysis. RESULTS: Out of 48 patients, 23 (48%) had a CVF on dCTM-BT, located at T1–5 (n = 4), T6–12 (n = 18), L1 (n = 1), with 70% on the right. CVF was identified in 22/22 (100%) of patients who had a high Bern score, 1/7 (14%) of those who had an intermediate score, and 0/19 (0%) of those who had a low score. The area under the ROC curve was 0.99 (95% CI, 0.98–1.00). The optimal cutoff was a Bern score of ≥5 (96% sensitivity, 100% specificity). CONCLUSIONS: dCTM-BT is feasible and has excellent diagnostic performance for CVF identification/localization. The Bern score is strongly associated with CVF detection and may help inform who will benefit from dCTM-BT.Keywords
This publication has 25 references indexed in Scilit:
- Respiratory Phase Affects the Conspicuity of CSF–Venous Fistulas in Spontaneous Intracranial HypotensionAmerican Journal of Neuroradiology, 2020
- Lateral Decubitus Digital Subtraction Myelography: Tips, Tricks, and PitfallsAmerican Journal of Neuroradiology, 2019
- Lateral decubitus digital subtraction myelography to identify spinal CSF–venous fistulas in spontaneous intracranial hypotensionJournal of Neurosurgery: Spine, 2019
- Assessing Spinal Cerebrospinal Fluid Leaks in Spontaneous Intracranial Hypotension With a Scoring System Based on Brain Magnetic Resonance Imaging FindingsJAMA Neurology, 2019
- Spontaneous Intracranial Hypotension: A Systematic Imaging Approach for CSF Leak Localization and Management Based on MRI and Digital Subtraction MyelographyAmerican Journal of Neuroradiology, 2019
- Decubitus CT Myelography for Detecting Subtle CSF Leaks in Spontaneous Intracranial HypotensionAmerican Journal of Neuroradiology, 2019
- Spontaneous Intracranial Hypotension: 10 Myths and MisperceptionsHeadache: The Journal of Head and Face Pain, 2018
- CSF–venous fistula in spontaneous intracranial hypotensionNeurology, 2014
- The International Classification of Headache Disorders, 3rd edition (beta version)Cephalalgia, 2013
- The Measurement of Observer Agreement for Categorical DataBiometrics, 1977