Primary stability and self‐tapping blades: biomechanical assessment of dental implants in medium‐density bone
Authors:
- 15 February 2011
- journal article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 22 (10) , 1179-1184
Abstract
Aim: The aim of this biomechanical study was to assess the influence of self‐tapping blades in terms of primary implant stability between implants with self‐tapping blades and implants without self‐tapping blades using five different analytic methods, especially in medium‐density bone.Materials and methods: Two different types of dental implants (4 × 10 mm) were tested: self‐tapping and non‐self‐tapping. The fixture design including thread profiles was exactly the same between the two groups; the only difference was the presence of cutting blades on one half of the apical portion of the implant body. Solid rigid polyurethane blocks with corresponding densities were selected to simulate medium‐density bone. Five mechanical assessments (insertion torque, resonance frequency analysis [RFA], reverse torque, pull‐out and push in test) were performed for primary stability.Results: Implants without self‐tapping blades showed significantly higher values (P0.05).Conclusions: The outcomes of the present study indicate that the implant body design without self‐tapping blades has a good primary stability compared with that with self‐tapping blades in medium‐density bone. Considering the RFA, a distinct layer of cortical bone on marginal bone will yield implant stability quotient values similar to those in medium‐bone density when implants have the same diameter.To cite this article: Kim Y‐S, Lim Y‐J. Primary stability and self‐tapping blades: biomechanical assessment of dental implants in medium‐density bone. Clin. Oral Impl. Res. 22, 2011; 1179–1184. doi: 10.1111/j.1600‐0501.2010.02089.xKeywords
This publication has 19 references indexed in Scilit:
- Primary Stability of a Hybrid Self-Tapping Implant Compared to a Cylindrical Non-Self-Tapping Implant with Respect to Drilling Protocols in an Ex Vivo ModelClinical Implant Dentistry and Related Research, 2011
- Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory studyClinical Oral Implants Research, 2009
- Effect of surface roughness, porosity, and a resorbable calcium phosphate coating on osseointegration of titanium in a minipig modelJournal of Biomedical Materials Research Part A, 2008
- Correlation Between Implant Stability Quotient and Bone‐Implant Contact: A Retrospective Histological and Histomorphometrical Study of Seven Titanium Implants Retrieved from HumansClinical Implant Dentistry and Related Research, 2006
- Peri‐Implant Bone Organization Under Immediate Loading State. Circularly Polarized Light Analyses: A Minipig StudyJournal of Periodontology, 2006
- Implant design and intraosseous stability of immediately placed implants: a human cadaver studyClinical Oral Implants Research, 2004
- Influence of implant taper on the primary and secondary stability of osseointegrated titanium implantsClinical Oral Implants Research, 2004
- Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implantsClinical Oral Implants Research, 2003
- A comparison between cutting torque and resonance frequency measurements of maxillary implantsInternational Journal of Oral and Maxillofacial Surgery, 1999
- Influence of mono- and bicortical anchorage on the integration of titanium implantsInternational Journal of Oral and Maxillofacial Surgery, 1996