Rankings
Publications
Search Publications
Cited-by Search
Sources
Publishers
Scholars
Scholars
Top Cited Scholars
Organizations
About
Scilit
About Us
Advisory Board
Data Sources
Career
Support / Contact
User Guide
Publisher User
Search Function
Rankings Function
API Resource
Scilit Knowledge
Metrics
Scilit Recognitions
Publications Classification
Media
News
Blog
Login
Register
Home
Publications
Accurate and efficient image intensifier distortion correction algorithm for volume tomographic angiography
Home
Publications
Accurate and efficient image intensifier distortion correction algorithm for volume tomographic angiography
Accurate and efficient image intensifier distortion correction algorithm for volume tomographic angiography
Authors:
XW
Xiaohui Wang
Xiaohui Wang
RN
Ruola Ning
Ruola Ning
Article Alert
Citation Alert
Add to Library
Cite
Download
Share
Download
Download PDF
Download
Publisher website
Google Scholar
1 March 1998
journal article
Published by
SPIE-Intl Soc Optical Eng
in
Optical Engineering
Vol. 37
(3)
,
977-983
DOI:
10.1117/1.601930
Abstract
The recent advance in image intensifier based volume tomographic angiography has stirred a significant interest in the development of accurate and efficient algorithms to correct image intensifier distortions. An algorithm and its calibration protocol are developed to correct the distortion caused by the image intensifier–CCD camera imaging chain in a single step regardless of distortion sources. This algorithm first partitions a distorted image into small quadrilateral regions, then maps each region individually to the corrected image using the corresponding bilinear functions. The general applicable parameters of these bilinear functions can be obtained using a specially designed grid phantom. The algorithm and the calibration protocol are tested using this grid phantom on a newly built image intensifier based volume tomographic angiography imaging system. The maximum distortion error is reduced from 5.96 mm before correction to 0.05 mm after correction. Further validation of the proposed algorithm is performed through three-dimensional tomographic reconstructions of a vascular phantom and animal studies. The reconstruction results indicate that the accuracy of the algorithm and the calibration protocol is acceptable for volume tomographic angiography. This algorithm can also be applied to radiation therapy and stereosurgical treatment planning where image intensifier distortions must be corrected. ©
1998 Society of Photo-Optical Instrumentation Engineers.
Keywords
ANGIOGRAPHY
DISTORTION
IMAGE INTENSIFIERS
Related articles
Cited
Cited by 8 articles
Scroll to top