Galvanic Deposition of Calcium Phosphate/Bioglass Composite Coating on AISI 316L
Authors:
- Claudio ZancaCZClaudio Zanca
- Alessandro MilazzoAMAlessandro Milazzo
- Simona CamporaSCSimona Campora
- Elisa CapuanaElisa Capuana
- Francesco Carfì PaviaFrancesco Carfì Pavia
- Bernardo PatellaBPBernardo Patella
- Francesco LoprestiFrancesco Lopresti
- Valerio BrucatoVBValerio Brucato
- Vincenzo La CarrubbaVincenzo La Carrubba
- Rosalinda InguantaRosalinda Inguanta
Open Access
Abstract
Calcium phosphate/Bioglass composite coatings on AISI 316L were investigated with regard to their potential role as a beneficial coating for orthopedic implants. These coatings were realized by the galvanic co-deposition of calcium phosphate compounds and Bioglass particles. A different amount of Bioglass 45S5 was used to study its effect on the performance of the composite coatings. The morphology and chemical composition of the coatings were investigated before and after their aging in simulated body fluid. The coatings uniformly covered the AISI 316L substrate and consisted of a brushite and hydroxyapatite mixture. Both phases were detected using X-ray diffraction and Raman spectroscopy. Additionally, both analyses revealed that brushite is the primary phase. The presence of Bioglass was verified through energy-dispersive X-ray spectroscopy, which showed the presence of a silicon peak. During aging in simulated body fluid, the coating was subject to a dynamic equilibrium of dissolution/reprecipitation with total conversion in only the hydroxyapatite phase. Corrosion tests performed in simulated body fluid at different aging times revealed that the coatings made with 1 g/L of Bioglass performed best. These samples have a corrosion potential of −0.068V vs. Ag/AgCl and a corrosion current density of 8.87 × 10−7 A/cm2. These values are better than those measured for bare AISI 316L (−0.187 V vs. Ag/AgCl and 2.52 × 10−6 A/cm2, respectively) and remained superior to pure steel for all 21 days of aging. This behavior indicated the good protection of the coating against corrosion phenomena, which was further confirmed by the very low concentration of Ni ions (0.076 ppm) released in the aging solution after 21 days of immersion. Furthermore, the absence of cytotoxicity, verified through cell viability assays with MC3T3-E1 osteoblastic cells, proves the biocompatibility of the coatings.Keywords
This publication has 106 references indexed in Scilit:
- Behavior of hydroxyapatite crystals in a simulated body fluid: effects of crystal faceJournal of the Ceramic Society of Japan, 2013
- A new route to grow oxide nanostructures based on metal displacement deposition. Lanthanides oxy/hydroxides growthElectrochimica Acta, 2012
- A review of protein adsorption on bioceramicsInterface Focus, 2012
- Comparison of bioactive glass coated and hydroxyapatite coated titanium dental implants in the human jaw boneAustralian Dental Journal, 2011
- First stages of bioactivity of glass-ceramics thin films prepared by magnetron sputtering techniqueMaterials Science and Engineering: B, 2010
- Osteoblast proliferation on hydroxyapatite coated substrates prepared by right angle magnetron sputteringJournal of Biomedical Materials Research Part A, 2009
- Bioactive ceramic-based materials with designed reactivity for bone tissue regenerationJournal of The Royal Society Interface, 2009
- Preparation of hydroxyapatite coating by the use of a sacrificial Mg anode methodCeramics International, 2007
- The nitrate reduction process: A way for increasing interfacial pHJournal of Electroanalytical Chemistry, 2007
- Interpretation of EIS data from accelerated exposure of coated metals based on modeling of coating physical propertiesElectrochimica Acta, 2006