Abstract
Diffusion‐weighted (DW) MRI has emerged as a key tool for assessing the microstructure of tissues in healthy and diseased states. Because of its rapid acquisition speed and insensitivity to motion, single‐shot echo‐planar imaging is the most common DW imaging technique. However, the presence of fat signal can severely affect DW‐echo planar imaging acquisitions because of the chemical shift artifact. Fat suppression is usually achieved through some form of chemical shift‐based fat saturation. Such methods effectively suppress the signal originating from aliphatic fat protons, but fail to suppress the signal from olefinic protons. Olefinic fat signal may result in significant distortions in the DW images, which bias the subsequently estimated diffusion parameters. This article introduces a method for removing olefinic fat signal from DW images, based on an echo time‐shifted acquisition. The method is developed and analyzed specifically in the context of single‐shot DW‐echo‐planar imaging, where image phase is generally unreliable. The proposed method is tested with phantom and in vivo datasets, and compared with a standard acquisition to demonstrate its performance. Magn Reson Med, 2011.Keywords
Funding Information
- NIH (P41-RR023953-01, P41-EB001977-21, R21-HL090455)
- NSF (CBET-07-30623)
This publication has 31 references indexed in Scilit:
- Robust water/fat separation in the presence of large field inhomogeneities using a graph cut algorithmMagnetic Resonance in Medicine, 2009
- Myofiber Ellipticity as an Explanation for Transverse Asymmetry of Skeletal Muscle Diffusion MRI In Vivo SignalAnnals of Biomedical Engineering, 2009
- Relaxation times of skeletal muscle metabolites at 7TJournal of Magnetic Resonance Imaging, 2009
- Efficient fat suppression by slice‐selection gradient reversal in twice‐refocused diffusion encodingMagnetic Resonance in Medicine, 2008
- Multiecho water‐fat separation and simultaneous R estimation with multifrequency fat spectrum modelingMagnetic Resonance in Medicine, 2008
- Composition of adipose tissue and marrow fat in humans by 1H NMR at 7 TeslaJournal of Lipid Research, 2008
- Noise considerations of three-point water-fat separation imaging methodsMedical Physics, 2008
- Method for efficient fast spin echo Dixon imagingMagnetic Resonance in Medicine, 2002
- Quantitative Analysis of Three-Dimensional-Resolved Fiber Architecture in Heterogeneous Skeletal Muscle Tissue Using NMR and Optical Imaging MethodsBiophysical Journal, 2001
- An inverse problem approach to the correction of distortion in EPI imagesIEEE Transactions on Medical Imaging, 2000