Standard 19mm St Jude aortic valves in patients with body surface less than 1.7m2
Open Access
- 1 April 2001
- journal article
- research article
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 24 (4) , 229-234
Abstract
Although new models of bileaflet valves with improved orifice have been devised, aortic valve replacement with 19mm prostheses still raises concerns about long term effects of residual transprosthetic gradient. We reviewed our experience with 19 mm standard model St Jude prostheses in 68 patients operated on between January 1983 and December 1995. Clinical late assessment was performed to evaluate the incidence of valve related complications. Postoperative echocardiography was performed to evaluate hemodynamic performance of the prostheses. Mean body surface area was 1.66±0.14m2. Late postoperative peak gradient was 53.85±7.16 mmHg; mean gradient was 34.80±5.55 mm Hg; effective orifice area was 1.93±0.05 cm2. Thirteen-year actuarial survival has been 90.89 ± 0.6%; thirteen-year freedom from embolism 89.41 ± 0.7% and freedom from hemorrhage 98.25 ± 0.02%. No case of prosthetic endocarditis, thrombosis, or reoperation was observed during follow-up.Keywords
This publication has 19 references indexed in Scilit:
- Influence of aortic valve replacement, prosthesis type, and size on functional outcome and ventricular mass in patients with aortic stenosisThe Journal of Thoracic and Cardiovascular Surgery, 1999
- Medium-term determinants of left ventricular mass index after stentless aortic valve replacementThe Annals of Thoracic Surgery, 1999
- Clinical patterns and trends of outcome of elderly patients with bronchogenic carcinomaEuropean Journal of Cardio-Thoracic Surgery, 1998
- Aortic Valve Replacement With a Small Mechanical Valve ProsthesisJapanese Circulation Journal, 1998
- Effects of Valve Substitute on Changes in Left Ventricular Function and Hypertrophy After Aortic Valve ReplacementThe Annals of Thoracic Surgery, 1996
- The risk of small St. Jude aortic valve prosthesesThe Annals of Thoracic Surgery, 1994
- Valve prosthesis hemodynamics and the problem of high transprosthetic pressure gradientsEuropean Journal of Cardio-Thoracic Surgery, 1992
- Flow characteristics of four commonly used mechanical heart valvesThe American Journal of Cardiology, 1986
- Bileaflet, tilting disc and porcine aortic valve substitutes: In vitro hydrodynamic characteristicsJACC, 1984