Tumour control probability (TCP) for non-uniform activity distribution in radionuclide therapy
Authors:
- Helena UusijärviHUHelena Uusijärvi
- Peter BernhardtPBPeter Bernhardt
- Eva Forssell-AronssonEva Forssell-Aronsson
- 25 July 2008
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (16) , 4369-4381
Abstract
Non-uniform radionuclide distribution in tumours will lead to a non-uniform absorbed dose. The aim of this study was to investigate how tumour control probability (TCP) depends on the radionuclide distribution in the tumour, both macroscopically and at the subcellular level. The absorbed dose in the cell nuclei of tumours was calculated for (90)Y, (177)Lu, (103m)Rh and (211)At. The radionuclides were uniformly distributed within the subcellular compartment and they were uniformly, normally or log-normally distributed among the cells in the tumour. When all cells contain the same amount of activity, the cumulated activities required for TCP = 0.99 ((approximate)A(TCP=0.99)) were 1.5-2 and 2-3 times higher when the activity was distributed on the cell membrane compared to in the cell nucleus for (103m)Rh and (211)At, respectively. TCP for (90)Y was not affected by different radionuclide distributions, whereas for (177)Lu, it was slightly affected when the radionuclide was in the nucleus. TCP for (103m)Rh and (211)At were affected by different radionuclide distributions to a great extent when the radionuclides were in the cell nucleus and to lesser extents when the radionuclides were distributed on the cell membrane or in the cytoplasm. When the activity was distributed in the nucleus, (approximate)A(TCP=0.99) increased when the activity distribution became more heterogeneous for (103m)Rh and (211)At, and the increase was large when the activity was normally distributed compared to log-normally distributed. When the activity was distributed on the cell membrane, (approximate)A(TCP=0.99) was not affected for (103m)Rh and (211)At when the activity distribution became more heterogeneous. (approximate)A(TCP=0.99) for (90)Y and (177)Lu were not affected by different activity distributions, neither macroscopic nor subcellular.Keywords
This publication has 21 references indexed in Scilit:
- Theoretical study of the influence of a heterogeneous activity distribution on intratumoral absorbed dose distributionMedical Physics, 2004
- Use of the Linear-Quadratic Radiobiological Model for Quantifying Kidney Response in Targeted RadiotherapyCancer Biotherapy and Radiopharmaceuticals, 2004
- Model of metastatic growth valuable for radionuclide therapyMedical Physics, 2003
- Low-energy Electron Emitters for Targeted Radiotherapy of Small TumoursActa Oncologica, 2001
- Dose-rate effects in targeted radiotherapyPhysics in Medicine & Biology, 1996
- Some characteristics of tumour control probability for heterogeneous tumoursPhysics in Medicine & Biology, 1996
- Absorbed doses for internal radiotherapy from 22 beta-emitting radionuclides: beta dosimetry of small spheresPhysics in Medicine & Biology, 1994
- Macroscopic dosimetry for radioimmunotherapy: Nonuniform activity distributions in solid tumorsMedical Physics, 1989
- Calculation of radiation doses for nonuniformly distributed β and γ radionuclides in soft tissueMedical Physics, 1985
- Dosimetric Precision Requirements in Radiation TherapyActa Radiologica: Oncology, 1984