The Cox-maze IV procedure for lone atrial fibrillation: a single center experience in 100 consecutive patients
- 22 February 2011
- journal article
- research article
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 31 (1) , 47-54
Abstract
Purpose The Cox-maze III procedure (CMP) has achieved high success rates for the surgical treatment of atrial fibrillation (AF). In 2002, our group introduced a simplified CMP, in which most incisions were replaced with linear lines of ablation using bipolar radiofrequency and cryoenergy. This operation, termed the CMP-IV, has significantly shortened operative times and allowed for a minimally invasive approach. This report evaluates our results in 100 consecutive patients undergoing a stand-alone CMP-IV. Methods Data were collected prospectively on 100 patients (mean age, 56 ± 10 years) who underwent a CMP-IV from January 2002 through May 2010. All patients were available for follow-up with a mean follow-up of 17 ± 10 months. Electrocardiograms or 24-h Holter monitorings were obtained at 6, 12, and 24 months. Data were analyzed using a longitudinal database containing over 380 variables. Results Thirty-one percent of patients had paroxysmal AF, with the remainder having persistent (6%) or longstanding persistent AF (63%). The mean preoperative duration of AF was 7.4 ± 6.7 years. The mean left atrial diameter was 4.7 ± 1.1 cm. In this group, 40 patients had failed with a mean of 2.6 ± 1.3 catheter ablations. Mean aortic cross-clamp time was 41 ± 13 min. There was one postoperative mortality. Postoperative freedom from AF was 93%, 90%, and 90% at 6, 12, and 24 months, respectively. Freedom from AF off antiarrhythmic medication was 82%, 82%, and 84% at 6, 12, and 24 months, respectively. Conclusion The less invasive CMP-IV has a high single procedure success rate, even with improved follow-up and stricter definitions of failure.Keywords
This publication has 41 references indexed in Scilit:
- The Cox maze IV procedure: Predictors of late recurrenceThe Journal of Thoracic and Cardiovascular Surgery, 2011
- A Minimally Invasive Cox-Maze Procedure Operative Technique and ResultsInnovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2010
- Results of a Minimally Invasive Surgical Pulmonary Vein Isolation and Ganglionic Plexi Ablation for Atrial FibrillationCirculation: Arrhythmia and Electrophysiology, 2009
- Predicting factors for atrial fibrillation acute termination during catheter ablation procedures: Implications for catheter ablation strategy and long-term outcomeHeart Rhythm, 2009
- Heart Disease and Stroke Statistics—2006 UpdateCirculation, 2006
- A New Era in the Surgical Treatment of Atrial FibrillationTransactions of the ... Meeting of the American Surgical Association, 2006
- Alternative Energy Sources for the Ablation of ArrhythmiasPacing and Clinical Electrophysiology, 2005
- Prevalence, age distribution, and gender of patients with atrial fibrillation. Analysis and implicationsArchives of internal medicine (1960), 1995
- Atrial fibrillation as an independent risk factor for stroke: the Framingham Study.Stroke, 1991
- Reaction of the myocardium to cryosurgery: electrophysiology and arrhythmogenic potential.Circulation, 1979