Stethoscope disinfection is rarely done in Ethiopia: What are the associated factors?
Open Access
- 27 June 2019
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (6) , e0208365
Abstract
The stethoscope, which is non-critical medical devices and a symbol of healthcare, is likely to be contaminated by pathogenic microorganisms and can play a contributory role in the transmission of hospital-acquired infection. And regular cleaning of the diaphragm of the stethoscope with a suitable disinfectant is decisive. However, in the resource-constrained setting like many healthcare facilities in Ethiopia healthcare provider’s stethoscope disinfection practice and its associated factors have not been well studied so far. Therefore, this study sought to determine stethoscope disinfection practice and associated factors among the healthcare providers in Addis Ababa, Ethiopia. A facility-based cross-sectional study was carried out between April and May 2016. For this study, 576 healthcare providers (physicians, health officers, nurses, midwives, and anesthesiologist) were included from 21 healthcare facilities in Addis Ababa. A pre-tested structured questionnaire was used for data collection. Descriptive statistics were computed. Bivariate and multivariable logistic regression analyses were used to identify factors that were significantly associated with stethoscope disinfection after every use. A total of 546 healthcare providers participated in this study, for a response rate of 94.7%. Two-fifths, 39.7% (95%CI: 35.9, 44.0%) of healthcare providers disinfecting their stethoscope after every use. And a significant number of participants 34.6% (95%CI: 30.8, 38.5%) never disinfect their stethoscope. Three out of four (76.0%) healthcare providers believe that stethoscope contamination can contribute to the transmission of infections. Safe infection prevention practice (AOR = 3.79, 95%CI: 2.45–5.84), awareness on infection prevention guideline (AOR = 1.93; 95%CI: 1.31, 2.82), and favorable attitude towards infection prevention (AOR = 1.73, 95%CI: 1.02, 2.93) were significantly associated with stethoscope disinfection after every use. The study also found that the odds of stethoscope disinfection were likely to be reduced by 79% among physicians than nurses (AOR = 0.21; 95%CI: 0.09, 0.49). Only a small proportion of healthcare providers disinfect their stethoscopes after every use. Factors such as safe infection prevention practice, awareness on infection prevention guidelines, and favorable attitude towards infection prevention were the independent predictors of stethoscopes disinfection after every use. Hence, promotion of stethoscope hygiene along with an educational program to enhance disinfection compliance in healthcare facilities may have a positive effect.Keywords
All Related Versions
This publication has 43 references indexed in Scilit:
- Bacterial contamination, bacterial profile and antimicrobial susceptibility pattern of isolates from stethoscopes at Jimma University Specialized HospitalAnnals of Clinical Microbiology and Antimicrobials, 2013
- Estimating hospital costs of catheter‐associated urinary tract infectionJournal of Hospital Medicine, 2013
- Predictors of stethoscope disinfection among pediatric health care providersAmerican Journal of Infection Control, 2012
- Burden of endemic health-care-associated infection in developing countries: systematic review and meta-analysisThe Lancet, 2011
- Nosocomial bacterial infections in a tertiary hospital in EthiopiaJournal of Infection Prevention, 2010
- Bacterial contamination of health care workers' white coatsAmerican Journal of Infection Control, 2009
- Bacterial contamination of stethoscopes with antimicrobial diaphragm coversAmerican Journal of Infection Control, 2007
- Methicillin-Resistant Staphylococcus aureus Survival on Hospital FomitesInfection Control & Hospital Epidemiology, 2006
- Contamination of Gowns, Gloves, and Stethoscopes With Vancomycin-Resistant EnterococciInfection Control & Hospital Epidemiology, 2001
- Role of Environmental Contamination in the Transmission of Vancomycin-Resistant EnterococciInfection Control & Hospital Epidemiology, 1997