Overcoming calcium blooming and improving the quantification accuracy of percent area luminal stenosis by material decomposition of multi-energy computed tomography datasets
- 1 October 2020
- journal article
- research article
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 7 (05) , 053501-16
Abstract
Purpose: Conventional stenosis quantification from single-energy computed tomography (SECT) images relies on segmentation of lumen boundaries, which suffers from partial volume averaging and calcium blooming effects. We present and evaluate a method for quantifying percent area stenosis using multienergy CT (MECT) images. Approach: We utilize material decomposition of MECT images to measure stenosis based on the ratio of iodine mass between vessel locations with and without a stenosis, thereby eliminating the requirement for segmentation of iodinated lumen. The method was first assessed using simulated MECT images created with different spatial resolutions. To experimentally assess this method, four phantoms with different stenosis severity (30% to 51%), vessel diameters (5.5 to 14 mm), and calcification densities (700 to 1100 mgHA / cc) were fabricated. Conventional SECT images were acquired using a commercial CT system and were analyzed with commercial software. MECT images were acquired using a commercial dual-energy CT (DECT) system and also from a research photon-counting detector CT (PCD-CT) system. Three-material-decomposition was performed on MECT data, and iodine density maps were used to quantify stenosis. Clinical radiation doses were used for all data acquisitions. Results: Computer simulation verified that this method reduced partial volume and blooming effects, resulting in consistent stenosis measurements. Phantom experiments showed accurate and reproducible stenosis measurements from MECT images. For DECT and two-threshold PCD-CT images, the estimation errors were 4.0% to 7.0%, 2.0% to 9.0%, 10.0% to 18.0%, and −1.0 % to −5.0 % (ground truth: 51%, 51%, 51%, and 30%). For four-threshold PCD-CT images, the errors were 1.0% to 3.0%, 4.0% to 6.0%, −1.0 % to 9.0%, and 0.0% to 6.0%. Errors using SECT were much larger, ranging from 4.4% to 46%, and were especially worse in the presence of dense calcifications. Conclusions: The proposed approach was shown to be insensitive to acquisition parameters, demonstrating the potential to improve the accuracy and precision of stenosis measurements in clinical practice.Keywords
This publication has 59 references indexed in Scilit:
- Guidelines for the Early Management of Patients With Acute Ischemic StrokeStroke, 2013
- Semi-automatic quantitative measurements of intracranial internal carotid artery stenosis and calcification using CT angiographyNeuroradiology, 2011
- Performance of Semiautomatic Assessment of Carotid Artery Stenosis on CT Angiography: Clarification of Differences with Manual AssessmentAmerican Journal of Neuroradiology, 2011
- Evaluation framework for carotid bifurcation lumen segmentation and stenosis gradingMedical Image Analysis, 2011
- Evaluation of Computer-Assisted Quantification of Carotid Artery StenosisJournal of Digital Imaging, 2011
- Analysis of Calcium in Carotid Plaques With Agatston Scores for Appropriate Selection of Surgical InterventionStroke, 2007
- Carotid Artery Diameter in Men and Women and the Relation to Body and Neck SizeStroke, 2006
- Preoperative Diagnosis of Carotid Artery StenosisStroke, 2002
- Evaluation of Cross-Sectional Luminal Morphology in Carotid Atherosclerotic Disease by Use of Spiral CT AngiographyStroke, 2001
- Cerebral angiographic risk in mild cerebrovascular disease.Stroke, 1990