Remote Photoplethysmography Technology for Blood Pressure and Hemoglobin Level Assessment in the Preoperative Assessment Setting: Algorithm Development Study
Open Access
- 6 June 2025
- journal article
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 9 (1) , e60455
Abstract
Background: Blood pressure (BP) and hemoglobin concentration measurements are essential components of preoperative anesthetic evaluation. Remote photoplethysmography (rPPG) is an emerging technology that may be used to measure BP and hemoglobin concentration noninvasively with just a consumer-grade smartphone, replacing traditional in-person measurements. However, there is limited data regarding the use of this technology in patients with diverse skin tones and medical comorbidities. Hence, widespread applicability is yet to be achieved. The potential benefits of achieving this would be immense, allowing for greater convenience, accessibility, and reduction in labor and resources. Objective: Our study aims to be the first to develop an algorithm for noninvasive rPPG-based BP and hemoglobin concentration measurement that can be used for preoperative evaluation of patients in real-world clinical practice settings. Methods: We conducted the study at Singapore General Hospital from March 1, 2023, to June 28, 2024. A total of 200 patients were recruited. Our primary analysis compared the accuracy of rPPG-based systolic and diastolic BP measurements against measurements taken with automated BP measuring devices. Our secondary analysis compared the accuracy of rPPG-based hemoglobin concentration measurement against traditional blood sampling. Results: Our model performed best with diastolic BP predictions, with a mean absolute percentage error of 7.52% and a mean difference of 0.16 mm Hg (SD 3.22 mm Hg) between reference and measured readings. The 95% CI for the mean difference between predicted and measured diastolic BP was ±0.57 (−0.41 to 0.73) mm Hg. Systolic BP predictions yielded a mean absolute percentage error of 9.52% and a mean difference of 2.69 mm Hg (SD 7.86 mm Hg). The 95% CI for the mean difference between predicted and measured systolic BP was ±1.14 (−1.54 to −3.83) mm Hg. Hemoglobin concentration predictions had a mean absolute percentage error of 8.52%, with a mean difference of 0.23 g/dL (SD 0.67 g/dL). The 95% CI for the mean difference between predicted and reference measured hemoglobin concentration was ±0.10 (95% CI 0.13‐0.33) g/dL. Conclusions: Noninvasive rPPG-based measurement of BP and hemoglobin concentration at the preoperative evaluation setting has great potential for improving convenience, improving efficiency, and conserving resources for patients and health care providers. Our model was able to accurately predict diastolic BP in patients with diverse skin tones and medical comorbidities. The findings of this study serve as a basis for further studies to develop and validate the model for noninvasive rPPG-based BP and hemoglobin concentration measurement.Keywords
This publication has 33 references indexed in Scilit:
- Remote photoplethysmography for heart rate measurement: A reviewBiomedical Signal Processing and Control, 2023
- 2023 ESH Guidelines for the management of arterial hypertension The Task Force for the management of arterial hypertension of the European Society of HypertensionJournal Of Hypertension, 2023
- CAMERA-BASED REMOTE PHOTOPLETHYSMOGRAPHY TO PREDICT BLOOD PRESSURE IN CLINIC PATIENTS WITH CARDIOVASCULAR DISEASEJournal Of Hypertension, 2023
- Remote patient monitoring using artificial intelligence: Current state, applications, and challengesWIREs Data Mining and Knowledge Discovery, 2023
- Evaluating the robustness of a contact-less mHealth solution for personal and remote monitoring of blood oxygen saturationJournal of Ambient Intelligence and Humanized Computing, 2022
- Perioperative Quality Initiative consensus statement on preoperative blood pressure, risk and outcomes for elective surgeryBritish Journal of Anaesthesia, 2019
- A universal standard for the validation of blood pressure measuring devicesJournal Of Hypertension, 2018
- Remote patient monitoring: a comprehensive studyJournal of Ambient Intelligence and Humanized Computing, 2017
- Impact of Blood Pressure Telemonitoring on Hypertension Outcomes: A Literature ReviewTelemedicine and e-Health, 2010
- The Aging Population and Its Impact on the Surgery WorkforceAnnals of Surgery, 2003