When one chip is not enough: Augmenting the validity of SELDI-TOF proteomic profiles of clinical specimens
- 15 January 2009
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (7) , 1014-1017
Abstract
To improve recovery, selectivity and reproducibility of SELDI-TOF analyses, we found it necessary to modify manufacturer's recommended protocols on sample and chip preparation. To yield reproducible denaturing conditions we verified concentrations of denaturing, reducing and lipid-solubilizing agents. We improved sorption of molecules of interest and reproducibility of analyses by introducing the preconditioning step and alkaline/acidic elutions for normal phase chips. The ratio that reproducibly decomposed the specimen was urea 9 mol l−1 + DTT 10 mmol l−1 + CHAPS 20 g l−1. For sample denaturation, 100 µl of the fresh mixture was added to 100 µl of the specimen. Our modification of a chip processing increased recovery of the NP20 chip by up to 400% as assessed by total ion current. We obtained the range of mass accuracy of 0.02–0.04% and response precision between 30–40% of m/z+. We observed about 50% peak overlap. To obtain approximately 92% of possible peaks three chip selectivities, IMAC, H50 and normal phase with alkaline wash should be used. The selectivity of the SELDI chips is affected by unspecific interactions of a sample with a chip backbone. The system is compatible with matrix-based biological materials and does not suffer from urea interference and sensitivity to covalently bound alkaline ions. The technique is reasonably suitable for semiquantitative screening in the mammalian low-molecular weight cellular, tissue and plasma proteome.Keywords
This publication has 11 references indexed in Scilit:
- Serum diagnosis of diffuse large B-cell lymphomas and further identification of response to therapy using SELDI-TOF-MS and tree analysis patterningBMC Cancer, 2007
- Validation of SELDI-TOF MS serum protein profiles for renal cell carcinoma in new populationsLaboratory Investigation, 2007
- Use of SELDI-TOF mass spectrometry for identification of new biomarkers: potential and limitationsClinical Chemistry and Laboratory Medicine (CCLM), 2007
- The blood peptidome: a higher dimension of information content for cancer biomarker discoveryNature Reviews Cancer, 2006
- Surface-Enhanced Laser Desorption Ionization/Time-of-Flight Mass Spectrometry Reveals Significant Artifacts in Serum Obtained from Clot Activator–Containing Collection DevicesClinical Chemistry, 2006
- Comparisons and validation of statistical clustering techniques for microarray gene expression dataBioinformatics, 2003
- Proteomic patterns in serum and identification of ovarian cancerThe Lancet, 2002
- Proteomic patterns in serum and identification of ovarian cancerThe Lancet, 2002
- Use of proteomic patterns in serum to identify ovarian cancerThe Lancet, 2002
- Recent advancements in surface-enhanced laser desorption/ionization-time of flight-mass spectrometryElectrophoresis, 2000