Smart Glasses: A New Tool for Assessing the Number of Patients in Mass-Casualty Incidents
Open Access
- 27 June 2022
- journal article
- research article
- Published by Cambridge University Press (CUP) in Prehospital and Disaster Medicine
- Vol. 37 (4) , 480-484
Abstract
Introduction: Mass-casualty incidents (MCIs) are events in which many people are injured during the same period of time. This has major implications in regards to practical concerns and planning for both personnel and medical equipment. Smart glasses are modern tools that could help Emergency Medical Services (EMS) in the estimation of the number of potential patients in an MCI. However, currently there is no study regarding the advantage of employing the use of smart glasses in MCIs in Thailand.Study Objective: This study aims to compare the overall accuracy and amount of time used with smart glasses and comparing it to manual counting to assess the number of casualties from the scene.Methods: This study was a randomized controlled trial, field exercise experimental study in the EMS unit of Srinagarind Hospital, Thailand. The participants were divided into two groups (those with smart glasses and those doing manual counting). On the days of the simulation (February 25 and 26, 2022), the participants in the smart glasses group received a 30-minute training session on the use of the smart glasses. After that, both groups of participants counted the number of casualties on the simulation field independently.Results: Sixty-eight participants were examined, and in the smart glasses group, a total of 58.8% (N = 20) of the participants were male. The mean age in this group was 39.4 years old. The most experienced in the EMS smart glasses group had worked in this position for four-to-six years (44.1%). The participants in the smart glasses group had the highest scores in accurately assessing the number of casualties being between 21-30 (98.0%) compared with the manual counting group (89.2%). Additionally, the time used for assessing the number of casualties in the smart glasses group was shorter than the manual counting group in tallying the number of casualties between 11-20 (6.3 versus 11.2 seconds; P = .04) and between 21-30 (22.1 versus 44.5 seconds; P = .02).Conclusion: The use of smart glasses to assess the number of casualties in MCIs when the number of patients is between 11 and 30 is useful in terms of greater accuracy and less time being spent than with manual counting.Keywords
This publication has 20 references indexed in Scilit:
- A call for collective learning from mass casualty incidentsInjury, 2021
- Students Experience Mass Casualty Nursing From the Patient Perspective in a Simulated Mass Casualty ExerciseNursing Education Perspectives, 2021
- Factors associated with physician decision making on withholding cardiopulmonary resuscitation in prehospital medicineScientific Reports, 2021
- Adaptation of Extended Reality Smart Glasses for Core Nursing Skill Training Among Undergraduate Nursing Students: Usability and Feasibility StudyJournal of Medical Internet Research, 2021
- Emergency physician’s dispatch by a paramedic-staffed emergency medical communication centre: sensitivity, specificity and search for a reference standardScandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 2021
- Smart glasses and video conferencing provide valuable medical student clinical exposure during COVID‐19AEM Education and Training, 2020
- Technical Support by Smart Glasses During a Mass Casualty Incident: A Randomized Controlled Simulation Trial on Technically Assisted Triage and Telemedical App Use in Disaster MedicineJournal of Medical Internet Research, 2019
- Comparison of Electronic Versus Manual Mass-Casualty Incident TriagePrehospital and Disaster Medicine, 2018
- Usability and Reliability of Smart Glasses for Secondary Triage During Mass Casualty Incidents2018
- Developing a Mass Casualty Surge Capacity Protocol for Emergency Medical Services to Use for Patient DistributionSouthern Medical Journal, 2017