Agreement between 2 SS-OCT biometry devices
Authors:
- Cameron McLintockCMCameron McLintock
- Shiney SeoSSShiney Seo
- Graham BarrettGBGraham Barrett
- James McKelvieJMJames McKelvie
- 24 March 2022
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (10) , 1107-1112
Abstract
Purpose: To assess the agreement between 2 swept-source optical coherence tomography biometry devices, Anterion and IOLMaster 700. Setting: Tertiary referral center, Brisbane, Australia. Design: Prospective comparative study. Methods: Bland-Altman analysis was used to assess agreement between devices for flat (K1), steep (K2), and mean (Km) keratometry for anterior, posterior, and total cornea, lens thickness (LT), anterior chamber depth (ACD), central corneal thickness (CCT), white to white (WTW), and axial length (AL). Generalized estimating equations were used to control for within-patient between-eye correlations. Interdevice differences were considered clinically significant if they were likely to alter the spherical refractive outcome by 0.25 diopter (D) or more. Results: 159 eyes of 91 patients (41 male, 50 female) were included. Statistically significant differences were found for K1, K2, and Km for anterior, posterior, and total cornea. When the Anterion was compared with the IOLMaster 700, the mean differences were as follows: anterior K1: −0.17 D, anterior K2: −0.18 D, anterior Km: −0.17 D, posterior K1: −0.38 D, posterior K2: −0.36 D, posterior Km: −0.37 D, total K1: −0.65 D, total K2: −0.82 D, and total Km: −0.74 D. The difference in posterior and total K metrics was clinically significant. Statistically significant differences were noted for LT: 0.159 mm, CCT: −0.004 mm, ACD: 0.054 mm, and WTW: −0.152 mm, although these were not found to be clinically significant. There was no significant difference between devices for AL. Conclusions: This study found statistically and clinically significant differences for both posterior and total keratometry between the Anterion and the IOLMaster 700. Posterior and total corneal parameters cannot be considered interchangeable between devices.Keywords
This publication has 20 references indexed in Scilit:
- Comparison of a New Swept-Source Anterior Segment Optical Coherence Tomography and a Scheimpflug Camera for Measurement of Corneal CurvatureCornea, 2020
- Comparison of two swept-source optical coherence tomography biometers and a partial coherence interferometerPLOS ONE, 2019
- Comparative analysis of 2 swept-source optical coherence tomography biometersJournal of Cataract & Refractive Surgery, 2019
- An Evaluation of the IOLMaster 700Eye & Contact Lens: Science & Clinical Practice, 2019
- Correcting Interdevice Bias of Horizontal White-to-White and Sulcus-to-Sulcus Measures Used for Implantable Collamer Lens SizingAmerican Journal of Ophthalmology, 2016
- Corneal Diameter as a Factor Influencing Corneal Astigmatism After Cataract SurgeryCornea, 2016
- Comparison and Repeatability of Keratometric and Corneal Power Measurements Obtained by Orbscan II, Pentacam, and Galilei Corneal Tomography SystemsAmerican Journal of Ophthalmology, 2013
- Contribution of posterior corneal astigmatism to total corneal astigmatismJournal of Cataract & Refractive Surgery, 2012
- Axial length measurement techniques in pediatric eyes with cataractSaudi Journal of Ophthalmology, 2012
- Calculation of intraocular lens power: a reviewActa Ophthalmologica Scandinavica, 2007