Impact of the Anesthetic Conserving Device on Respiratory Parameters and Work of Breathing in Critically Ill Patients under Light Sedation with Sevoflurane
Authors:
- Russell ChabanneRCRussell Chabanne
- Sebastien PerbetSPSebastien Perbet
- Emmanuel FutierEFEmmanuel Futier
- Nordine Ait Ben SaidNSNordine Ait Ben Said
- Samir JaberSJSamir Jaber
- Jean-Etienne BazinJBJean-Etienne Bazin
- Bruno PereiraBruno Pereira
- Jean-Michel ConstantinJCJean-Michel Constantin
- 1 October 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 121 (4) , 808-816
Abstract
Background: Sevoflurane sedation in the intensive care unit is possible with a special heat and moisture exchanger called the Anesthetic Conserving Device (ACD) (AnaConDa®; Sedana Medical AB, Uppsala, Sweden). The ACD, however, may corrupt ventilatory mechanics when used during the weaning process of intensive care unit patients. The authors compared the ventilatory effects of light-sedation with sevoflurane administered with the ACD and those of classic management, consisting of a heated humidifier and intravenous sedation, in intensive care unit patients receiving pressure-support ventilation. Methods: Fifteen intensive care unit patients without chronic pulmonary disease were included. A target Richmond Agitation Sedation Scale level of −1/−2 was obtained with intravenous remifentanil (baseline 1-condition). Two successive interventions were tested: replacement of the heated humidifier by the ACD without sedation change (ACD-condition) and sevoflurane with the ACD with an identical target level (ACD-sevoflurane-condition). Patients finally returned to baseline (baseline 2-condition). Work of breathing, ventilatory patterns, blood gases, and tolerance were recorded. A steady state of 30 min was achieved for each experimental condition. Results: ACD alone worsened ventilatory parameters, with significant increases in work of breathing (from 1.7 ± 1.1 to 2.3 ± 1.2 J/l), minute ventilation, P0,1, intrinsic positive end-expiratory pressure (from 1.3 ± 2.6 to 4.7 ± 4.2 cm H2O), inspiratory pressure swings, and decreased patient comfort. Sevoflurane normalized work of breathing (from 2.3 ± 1.2 to 1.8 ± 1 J/l), intrinsic positive end-expiratory pressure (from 4.7 ± 4.2 to 1.8 ± 2 cm H2O), inspiratory pressure swings, other ventilatory parameters, and patient tolerance. Conclusions: ACD increases work of breathing and worsens ventilatory parameters. Sevoflurane use via the ACD (for a light-sedation target) normalizes respiratory parameters. In this patient’s population, light-sedation with sevoflurane and the ACD may be possible during the weaning process.Keywords
This publication has 48 references indexed in Scilit:
- Sedation and Analgesia in the Mechanically Ventilated PatientAmerican Journal of Respiratory and Critical Care Medicine, 2012
- Toward Tailored Sedation with Halogenated Anesthetics in the Intensive Care Unit?Anesthesiology, 2010
- The Predictive Performance of a Pharmacokinetic Model for Manually Adjusted Infusion of Liquid Sevofluorane for Use with the Anesthetic-Conserving Device (AnaConDa): A Clinical StudyAnesthesia & Analgesia, 2008
- Isoflurane Inhalation Enhances Increased Physiologic Deadspace Volume Associated with Positive Pressure Ventilation and Compromises Arterial OxygenationAnesthesia & Analgesia, 2004
- Respiratory Mechanics During Sevoflurane Anesthesia in Children With and Without AsthmaAnesthesia & Analgesia, 1999
- The Combined Effects of Sevoflurane and Remifentanil on Central Respiratory Activity and Nociceptive Cardiovascular Responses in Anesthetized RabbitsAnesthesia & Analgesia, 1999
- SevofluraneDrugs, 1996
- P0.1 is a useful parameter in setting the level of pressure support ventilationIntensive Care Medicine, 1995
- A comparison of sevoflurane with halothane, enflurane, and isoflurane on bronchoconstriction caused by histamineCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1994
- Sevoflurane and Isoflurane Protect against Bronchospasm in DogsAnesthesiology, 1994