Cyclic fatigue resistance of VDW.ROTATE and Reciproc Blue nickel-titanium files at root canal temperature
Open Access
- 21 September 2020
- journal article
- research article
- Published by Maad Rayan Publishing Company in Journal of Dental Research, Dental Clinics, Dental Prospects
- Vol. 14 (3) , 177-180
Abstract
Background. This study aimed to compare the VDW.ROTATE instruments with the Reciproc Blue instruments in different kinematics in terms of the cyclic fatigue resistance. Methods. Sixty instruments, 40 VDW.ROTATE and 20 Reciproc Blue instruments, were divided into three groups (n=20): VDW.ROTATE was used in both continuous rotation and reciprocation, and Reciproc Blue was used in reciprocation only. The cyclic fatigue resistance test was carried out in an artificial canal (60°, r=3 mm) at an intracanal temperature of 35±2°C until fracture, and the time to fracture was recorded in seconds. The data were analyzed statistically using Kruskal–Wallis and Tamhane’s T2 tests (P<0.05). Results. DAll the reciprocating motion groups resulted in a longer mean duration to failure than the continuous rotation motion group (P<0.05). Conclusion. It was observed that the Reciproc Blue instruments had higher cyclic fatigue resistance than VDW.ROTATE instruments (P<0.05). Recent studies have shown that reciprocal movement increases cyclic fatigue resistance compared to rotational movement. The VDW.ROTATE instrument, which has a similar size, design, and alloy as the Reciproc Blue instrument, can also be used by clinicians in reciprocating motion with endo motors capable of reciprocating in different directions. However, even if the cyclic fatigue resistance increases by using VDW.ROTATE instruments in reciprocation, the cyclic fatigue resistance is lower than Reciproc Blue instruments.Keywords
This publication has 25 references indexed in Scilit:
- Cyclic fatigue analysis of Reciproc R25® instruments with different kinematicsAustralian Endodontic Journal, 2015
- In Vivo Intracanal Temperature Evolution during Endodontic Treatment after the Injection of Room Temperature or Preheated Sodium HypochloriteJournal of Endodontics, 2015
- Effect of movement kinematics on the cyclic fatigue resistance of nickel–titanium instrumentsInternational Endodontic Journal, 2015
- A review of instrumentation kinematics of engine‐driven nickel–titanium instrumentsInternational Endodontic Journal, 2015
- Comparison of Cyclic Fatigue Resistance of Nickel-Titanium Coronal Flaring InstrumentsJournal of Endodontics, 2014
- Deformation and fracture incidence of Reciproc instruments: a clinical evaluationInternational Endodontic Journal, 2014
- A comparison of cyclic fatigue resistance in reciprocating and rotary nickel‐titanium instrumentsAustralian Endodontic Journal, 2011
- Canal preparation using only one Ni‐Ti rotary instrument: preliminary observationsInternational Endodontic Journal, 2007
- Instrument fracture: mechanisms, removal of fragments, and clinical outcomesEndodontic Topics, 2007
- Effect of temperature on collagen-dissolving ability of sodium hypochlorite endodontic irrigantOral Surgery, Oral Medicine, Oral Pathology, 1980