Rapid acquisition of helium‐3 and proton three‐dimensional image sets of the human lung in a single breath‐hold using compressed sensing
- 21 October 2014
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 74 (4) , 1110-1115
Abstract
Purpose: To develop and validate a method for acquiring helium‐3 (3He) and proton (1H) three‐dimensional (3D) image sets of the human lung with isotropic spatial resolution within a 10‐s breath‐hold by using compressed sensing (CS) acceleration, and to assess the fidelity of undersampled images compared with fully sampled images.Methods: The undersampling scheme for CS acceleration was optimized and tested using3He ventilation data. Rapid 3D acquisition of both3He and1H data during one breath‐hold was then implemented, based on a balanced steady‐state free‐precession pulse sequence, by random undersampling of k‐space with reconstruction by means of minimizing the L1 norm and total variance. CS‐reconstruction fidelity was evaluated quantitatively by comparing fully sampled and retrospectively undersampled image sets.Results: Helium‐3 and1H 3D image sets of the lung with isotropic 3.9‐mm resolution were acquired during a single breath‐hold in 12 s and 8 s using acceleration factors of 2 and 3, respectively. Comparison of fully sampled and retrospectively undersampled3He and1H images yielded mean absolute errors 0.9.Conclusion: By randomly undersampling k‐space and using CS reconstruction, high‐quality3He and1H 3D image sets with isotropic 3.9‐mm resolution can be acquired within an 8‐s breath‐hold. Magn Reson Med 74:1110–1115, 2015.Keywords
Funding Information
- Siemens Medical Solutions
- the National Heart, Lung, and Blood Institute of the National Institutes of Health (R01 HL079077)
This publication has 15 references indexed in Scilit:
- Simultaneous Imaging of Lung Structure and Function with Triple-Nuclear Hybrid MR ImagingRadiology, 2013
- Incorporation of prior knowledge in compressed sensing for faster acquisition of hyperpolarized gas imagesMagnetic Resonance in Medicine, 2012
- Synchronous acquisition of hyperpolarised 3He and 1H MR images of the lungs – maximising mutual anatomical and functional informationNMR in Biomedicine, 2010
- Compressed sensing in hyperpolarized3He Lung MRIMagnetic Resonance in Medicine, 2010
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007
- Functional MRI of the lung using hyperpolarized 3‐helium gasJournal of Magnetic Resonance Imaging, 2004
- MRI of the lungs using hyperpolarized noble gasesMagnetic Resonance in Medicine, 2002
- Nuclear magnetic resonance imaging with hyperpolarised helium-3The Lancet, 1996
- The Lifting Scheme: A Custom-Design Construction of Biorthogonal WaveletsApplied and Computational Harmonic Analysis, 1996
- Biological magnetic resonance imaging using laser-polarized 129XeNature, 1994