Treatment planning and 4D robust evaluation strategy for proton therapy of lung tumors with large motion amplitude
Open Access
- 2 July 2021
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 48 (8) , 4425-4437
Abstract
Purpose: Intensity‐modulated proton therapy (IMPT) for lung tumors with a large tumor movement is challenging due to loss of robustness in the target coverage. Often an upper cut‐off at 5‐mm tumor movement is used for proton patient selection. In this study, we propose (1) a robust and easily implementable treatment planning strategy for lung tumors with a movement larger than 5 mm, and (2) a four‐dimensional computed tomography (4DCT) robust evaluation strategy for evaluating the dose distribution on the breathing phases.Materials and methods: We created a treatment planning strategy based on the internal target volume (ITV) concept (aim 1). The ITV was created as a union of the clinical target volumes (CTVs) on the eight 4DCT phases. The ITV expanded by 2 mm was the target during robust optimization on the average CT (avgCT). The clinical plan acceptability was judged based on a robust evaluation, computing the voxel‐wise min and max (VWmin/max) doses over 28 error scenarios (range and setup errors) on the avgCT. The plans were created in RayStation (RaySearch Laboratories, Stockholm, Sweden) using a Monte Carlo dose engine, commissioned for our Mevion S250i Hyperscan system (Mevion Medical Systems, Littleton, MA, USA). We developed a new 4D robust evaluation approach (4DRobAvg; aim 2). The 28 scenario doses were computed on each individual 4DCT phase. For each scenario, the dose distributions on the individual phases were deformed to the reference phase and combined to a weighted sum, resulting in 28 weighted sum scenario dose distributions. From these 28 scenario doses, VWmin/max doses were computed. This new 4D robust evaluation was compared to two simpler 4D evaluation strategies: re‐computing the nominal plan on each individual 4DCT phase (4DNom) and computing the robust VWmin/max doses on each individual phase (4DRobInd). The treatment planning and dose evaluation strategies were evaluated for 16 lung cancer patients with tumor movement of 4–26 mm.Results: The ratio of the ITV and CTV volumes increased linearly with the tumor amplitude, with an average ratio of 1.4. Despite large ITV volumes, a clinically acceptable plan fulfilling all target and organ at risk (OAR) constraints was feasible for all patients. The 4DNom and 4DRobInd evaluation strategies were found to under‐ or overestimate the dosimetric effect of the tumor movement, respectively. 4DRobInd showed target underdosage for five patients, not observed in the robust evaluation on the avgCT or in 4DRobAvg. The accuracy of dose deformation used in 4DRobAvg was quantified and found acceptable, with differences for the dose‐volume parameters below 1 Gy in most cases.Conclusion: The proposed ITV‐based planning strategy on the avgCT was found to be a clinically feasible approach with adequate tumor coverage and no OAR overdosage even for large tumor movement. The new proposed 4D robust evaluation, 4DRobAvg, was shown to give an easily interpretable understanding of the effect of respiratory motion dose distribution, and to give an accurate estimate of the dose delivered in the different breathing phases.Keywords
This publication has 34 references indexed in Scilit:
- Geometric uncertainties in voluntary deep inspiration breath hold radiotherapy for locally advanced lung cancerRadiotherapy and Oncology, 2016
- Proton pencil beam scanning for mediastinal lymphoma: the impact of interplay between target motion and beam scanningPhysics in Medicine & Biology, 2015
- The ANACONDA algorithm for deformable image registration in radiotherapyMedical Physics, 2015
- Clinical Implementation of Intensity Modulated Proton Therapy for Thoracic MalignanciesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2014
- The impact of respiratory gating on lung dosimetry in stereotactic body radiotherapy for lung cancerPhysica Medica, 2014
- Deep inspiration breath hold radiotherapy for locally advanced lung cancer: Comparison of different treatment techniques on target coverage, lung dose and treatment delivery timeActa Oncologica, 2013
- Motion Interplay as a Function of Patient Parameters and Spot Size in Spot Scanning Proton Therapy for Lung CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2013
- Dosimetric comparison of free-breathing and deep inspiration breath-hold radiotherapy for lung cancerStrahlentherapie und Onkologie, 2012
- Minimax optimization for handling range and setup uncertainties in proton therapyMedical Physics, 2011
- The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)Medical Physics, 2006