Agreement of infrared temporal artery thermometry with other thermometry methods in adults: systematic review
- 27 January 2016
- journal article
- review article
- Published by Wiley in Journal of Clinical Nursing
- Vol. 25 (7-8) , 894-905
Abstract
Aims and objectives: To critically review and synthesise the evidence on the agreement of temporal artery thermometry with invasive and noninvasive thermometry methods in hospitalised adults.Background: Noninvasive thermometry methods aim at combining patient comfort and ease of use with satisfactory accuracy of temperature measurements. Infrared temporal artery thermometry is based on the detection of heat radiated from this artery in the forehead and temporal region.Design: Systematic literature review.Methods: A literature search was conducted in Pubmed,CINAHL, Cochrane Library, Web of Science and Embase. Data were extracted from twenty method‐comparison studies published between 2002–2015. Methodological quality of selected studies was evaluated.Results: Temperature measurements of temporal artery were compared with pulmonary artery, urinary bladder, oesophageal or nasopharyngeal ones in eight studies for the whole temperature range. Accuracy and precision of temporal artery thermometry exceeded recommended levels of 0·3°C in three and six studies respectively. Likewise, in nine studies that compared temporal artery temperature measurements with oral and ear‐based ones, satisfactory agreement and variability was reported in five and none of them respectively. With regard to fever and hypothermia, although specificity of temporal artery thermometers for detecting these disorders was satisfactory, their sensitivity was low.Conclusions: Existing evidence does not support that temporal artery thermometry can replace common invasive and noninvasive thermometry methods in adult patients.Relevance to clinical practice: Health care professionals are recommended to avoid the use of infrared temporal artery temporal artery thermometry in adults, or be cautious about the accuracy and precision of its readings, until improved devices are developed.Keywords
This publication has 27 references indexed in Scilit:
- Clinical Nurse Specialist-Led Evaluation of Temporal Artery Thermometers in Acute CareClinical Nurse Specialist, 2010
- Temporal Artery versus Bladder Thermometry during Adult Medical-Surgical Intensive Care Monitoring: An Observational StudyBMC Anesthesiology, 2010
- A comparison of technologies used for estimation of body temperaturePhysiological Measurement, 2010
- Noninvasive Temperature Monitoring in Postanesthesia Care UnitsAnesthesiology, 2009
- Noninvasive Measurement of Body Temperature in Critically Ill PatientsCritical Care Nurse, 2009
- Evaluating the Accuracy of Four Temperature Instruments on an Adult Inpatient Oncology UnitClinical Journal of Oncology Nursing, 2008
- Temporal Artery Versus Bladder Thermometry During Perioperative and Intensive Care Unit MonitoringAnesthesia & Analgesia, 2007
- Accuracy of Noninvasive Core Temperature Measurement in Acutely Ill Adults: The State of the ScienceBiological Research For Nursing, 2006
- Insufficiency in a New Temporal-Artery Thermometer for Adult and Pediatric PatientsAnesthesia & Analgesia, 2002
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986