Influence of GFRP Confinement of Reinforced Concrete Columns on the Corrosion of Reinforcing Steel in a Salt Water Environment
- 1 January 2015
- journal article
- research article
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 27 (1)
Abstract
This paper concentrates on the changes on the corrosion rate of the steel bars of RC columns due to their wrapping with glass fiber–reinforced polymers (GFRPs). RC cylindrical laboratorial specimens, both unwrapped and wrapped with GFRP, were immersed in a sodium chloride solution for 20 months. The changes on concrete resistivity and the corrosion process were followed by open potential measurements and electrochemical impedance. It was possible to quantify the influence of the GFRP jackets in the solution uptake and on the corrosion of the steel reinforcement. The results showed a delay on the diffusion of the solution into concrete due to the presence of the GFRP, which allowed that the bars remained in a passive state for longer immersion periods. The GFRP barrier lowered the rate of uptake of the solution and the chloride ion penetration. However, the GFRP jacket may have the properties as a physical barrier reduced due to imperfect application. The incomplete concrete saturation makes oxygen available, thus promoting an intense corrosion activity at the rebars.Keywords
This publication has 39 references indexed in Scilit:
- Bond–slip on CFRP/GFRP-to-concrete joints subjected to moisture, salt fog and temperature cyclesComposites Part B: Engineering, 2013
- Effects of harsh weather and seawater on glass fiber reinforced epoxy compositeJournal of Reinforced Plastics and Composites, 2010
- Corrosion of steel reinforcements embedded in FRP wrapped concreteConstruction and Building Materials, 2009
- Coatings for Concrete Protection against Aggressive EnvironmentsJournal of Advanced Concrete Technology, 2008
- Aging of GFRP laminates and confinement of concrete columnsComposite Structures, 2007
- Corrosion rate of ordinary and high-performance concrete subjected to chloride attack by AC impedance spectroscopyConstruction and Building Materials, 2006
- Fundamentals of Impedance Spectroscopy2005
- Concrete columns confined by fiber composite wraps under combined axial and cyclic lateral loadsComposite Structures, 2002
- Electrochemical behaviour of steel rebars in concrete: influence of environmental factors and cement chemistryElectrochimica Acta, 2001
- Accelerated corrosion and repair of reinforced concrete columns using carbon fibre reinforced polymer sheetsCanadian Journal of Civil Engineering, 2000