Extent of posterior wall lesion following pulmonary vein isolation with pentaspline pulsed field and cryoballoon ablation: the potential role of deployment technique
Open Access
- 7 October 2026
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 13, 1880750
Abstract
Background: Pulmonary vein isolation (PVI) using cryoballoon (CB) or pulsed field ablation (PFA) with a pentaspline catheter achieves similar efficacy in atrial fibrillation (AF), but lesion extension on the left atrial posterior wall (LAPW) may differ. Pentaspline-PFA (P-PFA) has been reported to create broader LAPW lesions, potentially leaving narrow viable corridors that have been hypothesized to be proarrhythmic. Objective: To descriptively compare the extent of chronic unintended left atrial posterior wall isolation after PVI with P-PFA and CB ablation. Methods: We conducted a single-center ambispective study including consecutive patients undergoing repeat left atrial mapping after index PVI with either P-PFA, using a protocol designed to ensure catheter alignment with the pulmonary veins, or CB. Patients with additional LA ablation between index procedure and remapping, unrelated LAPW scarring, or posterior pulmonary vein gaps were excluded. The primary endpoint was isolated LAPW area. Secondary endpoints included percentage of isolated LAPW and minimum residual corridor width. Results: Seventy-four patients were included in the analysis: 49 P-PFA and 25 CB. Mean age was 64.2 ± 10.0 years, 64.9% were male, and 55.4% had persistent AF. Isolated LAPW area was 8.3 ± 4.0 cm 2 in the P-PFA group and 9.5 ± 3.9 cm 2 in the CB group, with no statistically significant difference detected between groups (mean difference −1.26 cm 2 , 95% CI: −3.22 to 0.70; p = 0.203). The percentage of isolated LAPW area was 39.9 ± 17.6% vs. 38.9 ± 14.9% ( p = 0.805), and minimum residual corridor width was 19.7 ± 9.9 vs. 18.6 ± 11.0 mm ( p = 0.671), respectively. P-PFA was associated with shorter procedure time (44.2 ± 10.2 vs. 65.8 ± 24.6 min; p < 0.001), shorter LA dwell time (38.1 ± 9.6 vs. 60.6 ± 20.5 min; p < 0.001), lower fluoroscopy time (5.3 ± 3.9 vs. 13.0 ± 9.7 min; p < 0.001), and lower dose–area product [5.3 (2.8–9.7) vs. 19.3 (6.5–31.0) Gy·cm 2 ; p < 0.001]. Conclusion: In this descriptive, hypothesis-generating study, no statistically significant difference in chronic LAPW isolation extent was detected between P-PFA and CB ablation. These findings support the hypothesis that catheter deployment technique may influence posterior wall lesion geometry, warranting confirmation in adequately powered prospective studies.Keywords
This publication has 28 references indexed in Scilit:
- 2026 HRS/EHRA Scientific Statement on Pulsed Field Ablation for Cardiac ArrhythmiasHeart Rhythm, 2026
- Head-to-head comparison of pulsed-field ablation, high-power short-duration ablation, cryoballoon and conventional radiofrequency ablation by MRI-based ablation lesion assessmentJournal of Interventional Cardiac Electrophysiology, 2025
- Pulsed Field or Cryoballoon Ablation for Paroxysmal Atrial FibrillationNew England Journal of Medicine, 2025
- Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K studyNature Medicine, 2024
- How to perform pulmonary vein isolation using a pentaspline pulsed field ablation system for treatment of atrial fibrillationHeart Rhythm, 2024
- Pulsed Field or Conventional Thermal Ablation for Paroxysmal Atrial FibrillationNew England Journal of Medicine, 2023
- Electroanatomic Characterization and Ablation of Scar-Related Isthmus Sites Supporting Perimitral FlutterJACC: Clinical Electrophysiology, 2021
- Pulsed Field Ablation in Patients With Persistent Atrial FibrillationJACC, 2020
- Validating Left Atrial Low Voltage Areas During Atrial Fibrillation and Atrial Flutter Using Multielectrode Automated Electroanatomic MappingJACC: Clinical Electrophysiology, 2018
- Quantification of the cryoablation zone demarcated by pre- and postprocedural electroanatomic mapping in patients with atrial fibrillation using the 28-mm second-generation cryoballoonHeart Rhythm, 2015