Modeling Corrosion Progress of Steel Wires in External Tendons
- 1 December 2018
- journal article
- research article
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 23 (12)
Abstract
When prestressing tendons are corroded, a bridge owner must decide whether to replace or repair them. If this decision must be based on a destructive inspection method, section losses in the steel strands must be estimated by measuring either the corrosion depth or the perimeter of the corrosion area. For this study, models for the determination of corrosion progress in corroded wires were investigated in a preliminary study of evaluating section losses in strands. Corroded strands were sampled from a post-tensioned concrete box-girder bridge that demonstrated external tendon failure due to chloride- and moisture-induced corrosion. The strands were cut into equidistant lengths, and the corroded areas of the cross sections were measured. Analysis showed that using models of existing corrosion progress routinely underestimated the section losses for maximum corrosion depth. Actual measurements showed that corrosion rapidly progressed along the perimeter in the earlier stages, and the result was a corroded surface with a convex shape. Herein, new corrosion-progress models that more-accurately reflect the actual corroded sections of wires are proposed. Although the measurements showed a large degree of dispersion, the proposed models were verified as more effective in estimating section losses.Keywords
This publication has 17 references indexed in Scilit:
- Use of a 3D optical measurement technique for stochastic corrosion pattern analysis of reinforcing bars subjected to accelerated corrosionCorrosion Science, 2013
- Generalized Probabilistic Framework for Optimum Inspection and Maintenance PlanningJournal of Structural Engineering, 2013
- Time-Dependent Reliability of PSC Box-Girder Bridge Considering Creep, Shrinkage, and CorrosionJournal of Bridge Engineering, 2011
- Seismic assessment of existing RC structures affected by degradation phenomenaStructural Safety, 2009
- Spatial time-dependent reliability analysis of corroding pretensioned prestressed concrete bridge girdersStructural Safety, 2007
- Residual Life of Corroding Reinforced Concrete Structures in Marine EnvironmentJournal of Materials in Civil Engineering, 2003
- Time-dependent reliability of deteriorating reinforced concrete bridge decksStructural Safety, 1998
- Reliability of Deteriorating RC Slab BridgesJournal of Structural Engineering, 1997
- Comparison of rates of general corrosion and maximum pitting penetration on concrete embedded steel reinforcementCement and Concrete Research, 1995
- Evaluation of corrosion failure by extreme value statistics.ISIJ International, 1991