Evaluation of Retentive Force and Long-Term Performance of 4 Mol% Yttria Partially Stabilized Zirconia (4Y-PSZ) Double Crowns
Authors:
Open Access
- 14 December 2024
- journal article
- Published by Springer Nature in Cureus
- Vol. 16 (12) , e75705
Abstract
Purpose: This study aims to evaluate the effects of taper angle and the number of insertion-removal cycles on the retention force of 4 mol% yttria partially stabilized zirconia (4Y-PSZ) double crowns over time. Materials and methods: Primary and secondary crowns were fabricated using 4Y-PSZ with taper angles of 2°, 4°, and 6° (n=15). Retention force during crown removal was measured after applying 50-N and 100-N loads. Insertion-removal cycles were performed at 0, 2500, 5000, 7500, and 10,000 cycles, and retention force was assessed at each stage. Contact conditions between the inner and outer crowns were evaluated via color mapping at 0 and 10,000 cycles. Two-way ANOVA was used for statistical analysis, followed by Tukey's test for multiple comparisons. Results: Retention force significantly decreased with smaller taper angles and higher cycle numbers (p<0.01). For a taper angle of 4°, the initial retention force of 10.36 N decreased significantly to 5.98 N after 10,000 cycles (p<0.01). For a taper angle of 6°, the initial retention force of 1.64 N dropped to 0.03 N after 10,000 cycles. Color mapping revealed continuous contact along the axial surface, with strong point contacts, particularly in the central axial region. Smaller taper angles exhibited stronger contact points, which decreased with repeated cycles, indicating changes in contact conditions. Conclusions: Higher retentive forces were achieved with increased loading pressures and smaller taper angles, while repeated insertion-removal cycles led to a progressive reduction in retention. These findings provide foundational data supporting the clinical application of 4Y-PSZ double crowns.Keywords
This publication has 23 references indexed in Scilit:
- Impact of material combinations and removal and insertion cycles on the retention force of telescopic systemsClinical Oral Investigations, 2023
- In vitro investigations on retention force behavior of conventional and modern double crown systemsDental Materials, 2021
- Retention behavior of double-crown attachments with zirconia primary and secondary crownsDental Materials, 2016
- Retention and surface changes of zirconia primary crowns with secondary crowns of different materialsClinical Oral Investigations, 2014
- A Systematic Review of the Clinical Performance of Tooth‐Retained and Implant‐Retained Double Crown Prostheses with a Follow‐Up of ≥3 YearsJournal of Prosthodontics, 2012
- Conical crowns with electroplated gold copings: retention force changes caused by wear and combined off-axial loadClinical Oral Implants Research, 2010
- Frequency and costs of technical failures of clasp- and double crown-retained removable partial denturesClinical Oral Investigations, 2002
- New telescopic crown design for removable partial denturesThe Journal of Prosthetic Dentistry, 1999
- Japanese tooth size: Past and presentAmerican Journal of Physical Anthropology, 1982
- Telescope retainers and their clinical applicationThe Journal of Prosthetic Dentistry, 1980