Do the number of basis images and metal artifact reduction affect the production of artifacts near and far from zirconium dental implants in CBCT?
- 24 February 2021
- journal article
- research article
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 25 (9) , 5281-5291
Abstract
Objectives This study aimed to evaluate the influence of the number of basis images and the metal artifact reduction (MAR) tool on the production of artifacts near and far from a zirconium implant in cone-beam computed tomography (CBCT). Materials and methods CBCT scans of a mandible were acquired before and after insertion of an implant, using 450 and 720 basis images, with and without MAR activation. The mean and standard deviation (SD) of the gray values of the regions of interest (ROIs) located on the cortices adjacent to the implant and at different distances from it (in the soft tissue) were calculated. The mean of the gray values was used to calculate the absolute contrast difference (ACD) between the control and implant scans. Results In general, the number of basis images did not affect the SD and the ACD values of the buccal and lingual ROIs (p > 0.05). The implant increased the SD in the lingual cortical plate (p < 0.05). In this case, MAR activation decreased SD (p < 0.05). All ROIs located at different distances from the implant showed higher SD on scans acquired with 450 basis images (p < 0.05), regardless of MAR condition. Conclusions A higher number of basis images reduces the magnitude of artifacts but does not influence the image quality in bone cortical plates. MAR improves the image in the areas most affected by artifacts. Clinical relevance The number of basis images is known as a factor capable of influencing the image quality and radiation dose for the patient. Therefore, it is important to investigate its effect on the expression of artifacts in the CBCT images.Keywords
Funding Information
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (001)
This publication has 28 references indexed in Scilit:
- Influence of basis images and skull position on evaluation of cortical bone thickness in cone beam computed tomographyOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2017
- Evaluation of a metal artefact reduction tool on different positions of a metal object in the FOVDentomaxillofacial Radiology, 2017
- The effect of milliamperage, number of basis images, and export slice thickness on contrast-to-noise ratio and detection of mandibular canal on cone beam computed tomography scans: an in vitro studyOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2016
- Metal Artifact Reduction in CT: Where Are We After Four Decades?IEEE Access, 2016
- Efficacy of a cone beam computed tomography metal artifact reduction algorithm for the detection of peri-implant fenestrations and dehiscencesOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2016
- Assessment of furcal perforations in the vicinity of different root canal sealers using a cone beam computed tomography system with and without the application of artifact reduction mode: an ex vivo investigation on extracted human teethOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2016
- Effect of exposure parameters and voxel size on bone structure analysis in CBCTDentomaxillofacial Radiology, 2015
- Assessment of buccal marginal alveolar peri-implant and periodontal defects using a cone beam CT system with and without the application of metal artefact reduction modeDentomaxillofacial Radiology, 2013
- Quantification of metal artifacts on cone beam computed tomography imagesClinical Oral Implants Research, 2011
- Artefacts in CBCT: a reviewDentomaxillofacial Radiology, 2011