Biomechanical Evaluation of Initial Stability of a Root Analogue Implant Design with Drilling Protocol: A 3D Finite Element Analysis
Open Access
- 15 June 2020
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 10 (12) , 4104
Abstract
Background: The aim of this study was to biomechanically evaluate the initial stability of a patient-specific root analogue implant (RAI) design with drilling protocol by comparing it to designs without drilling protocol through a 3D finite element analysis (FEA). Methods: A 3D surface model of an RAI for the upper right incisor was constructed. To evaluate the effect of root apex drilling, four modified RAI shapes were designed with the press-fit implantation method: Non-modified, wedge added at root surface, lattice added at root surface, and apex-anchor added at root apex (AA). Each model was subjected to an oblique load of 100 N. To simulate the initial stability of implantation, contact conditions at the implant–bone interface were set to allow for the sliding phenomenon with low friction (frictional coefficient 0.1–0.5). Analysis was performed to evaluate micro-displacements of the implants and peak stress on the surrounding bones. Results: Under all low frictional coefficient conditions, the lowest von Mises stress level on the cortical bone and fewest micro-displacements of the implant were observed in the AA design. Conclusion: In view of these results, the AA design proved superior in reducing the stress concentration on the supporting cortical bone and the micro-displacement of RAI.Keywords
Funding Information
- Ministry of Trade, Industry and Energy (20001221)
This publication has 33 references indexed in Scilit:
- Designing Natural-Tooth-Shaped Dental Implants based on Soft-Kill Option OptimizationComputer-Aided Design and Applications, 2013
- Accuracy of preemptively constructed, Cone Beam CT‐, and CAD/CAM technology‐based, individual Root Analogue Implant technique: An in vitro pilot investigationClinical Oral Implants Research, 2012
- Custom-made, root-analogue direct laser metal forming implant: a case reportLasers in Medical Science, 2012
- Immediate, single stage, truly anatomic zirconia implant in lower molar replacement: A case report with 2.5 years follow-upInternational Journal of Oral and Maxillofacial Surgery, 2011
- Morphometric analysis of the anterior region of the maxillary bone for immediate implant placement using micro‐CTClinical Anatomy, 2011
- Immediate, non-submerged, root-analogue zirconia implants placed into single-rooted extraction sockets: 2-year follow-up of a clinical studyInternational Journal of Oral and Maxillofacial Surgery, 2009
- Bone stress and interfacial sliding analysis of implant designs on an immediately loaded maxillary implant: A non-linear finite element studyJournal of Dentistry, 2008
- Artificial composite bone as a model of human trabecular bone: The implant–bone interfaceJournal of Biomechanics, 2007
- Effects of Implant Thread Geometry on Percentage of Osseointegration and Resistance to Reverse Torque in the Tibia of RabbitsJournal of Periodontology, 2004
- Healing‐in of root analogue titanium implants placed in extraction sockets. An experimental study in the beagle dog.Clinical Oral Implants Research, 1992