Balloon guide catheters: use, reject, or randomize?
- 8 June 2021
- journal article
- editorial
- Published by Springer Nature in Neuroradiology
- Vol. 63 (8) , 1179-1183
Abstract
Thrombectomy devices played an important role in the success of endovascular treatment trials over the past five years. A balloon guide catheter (BGC) is an adjunctive device used to arrest and reverse flow by inflating the balloon at its tip, which allows for flow reversal in intracranial arteries during retrieval of thrombectomy devices by applying concomitant aspiration through its lumen. Thereby, it can decrease the risk of clot fragmentation and distal embolization. Despite the numerous benchtop and clinical observational studies showing the superiority of BGC to conventional guide catheters in improving reperfusion quality and clinical outcome, its use is still low in clinical practice. The reasons behind this reluctance might be related to technical and cost issues. Therefore, high level evidence data, i.e., a randomized clinical trial, are needed to increase its implementation in thrombectomy procedures. Nonetheless, several obstacles and challenges can prevent the completion of such a trial, and efforts are needed to overcome them. We provide an overview of the current opinions about BGCs in the neurointerventional community and discuss the feasibility and challenges of a possible randomized trial to answer the question “should a BGC be routinely used in endovascular treatment of acute ischemic stroke?”Keywords
This publication has 27 references indexed in Scilit:
- Transradial versus transfemoral access for anterior circulation mechanical thrombectomy: comparison of technical and clinical outcomesJournal of NeuroInterventional Surgery, 2019
- Reperfusion and Clinical Outcomes in Acute Ischemic Stroke: Systematic Review and Meta-Analysis of the Stent-Retriever-Based, Early Window Endovascular Stroke TrialsFrontiers in Neurology, 2018
- First Pass EffectStroke, 2018
- Impact of balloon guide catheter on technical and clinical outcomes: a systematic review and meta-analysisJournal of NeuroInterventional Surgery, 2017
- Comparison of a Balloon Guide Catheter and a Non–Balloon Guide Catheter for Mechanical ThrombectomyRadiology, 2016
- The Heidelberg Bleeding ClassificationStroke, 2015
- Groin complications in endovascular mechanical thrombectomy for acute ischemic stroke: a 10-year single center experienceJournal of NeuroInterventional Surgery, 2015
- Balloon Guide Catheter Improves Revascularization and Clinical Outcomes With the Solitaire DeviceStroke, 2014
- Recommendations on Angiographic Revascularization Grading Standards for Acute Ischemic StrokeStroke, 2013
- Measurement of health statusControlled Clinical Trials, 1989