IFCC Working Group Recommendations for Assessing Commutability Part 1: General Experimental Design
Open Access
- 1 March 2018
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 64 (3) , 447-454
Abstract
Commutability is a property of a reference material (RM) that relates to the closeness of agreement between results for an RM and results for clinical samples (CSs) when measured by ≥2 measurement procedures (MPs). Commutability of RMs used in a calibration traceability scheme is an essential property for them to be fit for purpose. Similarly, commutability of trueness controls or external quality assessment samples is essential when those materials are used to assess trueness of results for CSs. This report is part 1 of a 3-part series describing how to assess commutability of RMs. Part 1 defines commutability and addresses critical components of the experimental design for commutability assessment, including selection of individual CSs, use of pooled CSs, qualification of MPs for inclusion, establishing criteria for the determination that an RM is commutable, generalization of commutability conclusions to future measurements made with the MPs included in the assessment, and information regarding commutability to be included in the certificate for an RM. Parts 2 and 3 in the series present 2 different statistical approaches to commutability assessment that use fixed criteria related to the medical decisions that will be made using the laboratory test results.Keywords
This publication has 6 references indexed in Scilit:
- IFCC Working Group Recommendations for Assessing Commutability Part 2: Using the Difference in Bias between a Reference Material and Clinical SamplesClinical Chemistry, 2018
- IFCC Working Group Recommendations for Assessing Commutability Part 3: Using the Calibration Effectiveness of a Reference MaterialClinical Chemistry, 2018
- Commutability Assessment of External Quality Assessment Materials with the Difference in Bias Approach: Are Acceptance Criteria Based on Medical Requirements too Strict?Clinical Chemistry, 2016
- Difference in Bias Approach for Commutability Assessment: Application to Frozen Pools of Human Serum Measured by 8 Direct Methods for HDL and LDL CholesterolClinical Chemistry, 2015
- Performance criteria for combined uncertainty budget in the implementation of metrological traceabilityClinical Chemistry and Laboratory Medicine (CCLM), 2015
- Defining analytical performance specifications 15 years after the Stockholm conferenceClinical Chemistry and Laboratory Medicine (CCLM), 2015