Frontal Analysis Capillary Electrophoresis Hyphenated to Electrospray Ionization Mass Spectrometry for the Characterization of the Antithrombin/Heparin Pentasaccharide Complex
- 31 May 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (13) , 4987-4993
Abstract
The interaction of proteins with polysaccharides represents a major and challenging topic in glycobiology, since such complexes mediate fundamental biological mechanisms. A new strategy based on the hyphenation of frontal analysis capillary electrophoresis (FACE) with electrospray ionization mass spectrometry (ESIMS) is reported for the characterization of protein/carbohydrate complexes. While most of the previously reported CE−MS experiments were performed using capillary electrophoresis in zone format, we report for the first time CE−MS experiments in which CE was performed in frontal analysis (FACE−MS). We showed that the frontal mode offered a better sensitivity than zone mode and was well suited for the CE−MS coupling. This FACE−MS coupling was applied to the analysis of the complex between antithrombin and the sulfated pentasaccharide reproducing the antithrombin-binding sequence in heparin. The mixture of coincubated antithrombin and heparin pentasaccharide was continuously injected into the capillary, and the electrophoretic separation of the free and bound forms of the protein was achieved. The intact noncovalent complex antithrombin/heparin pentasaccharide was detected on-line by ESIMS in positive ionization mode and in nondenaturing sheath liquid conditions. The complex stoichiometry was determined from the mass measurement of the complex. In addition, the characterization of the sulfated pentasaccharide ligand dissociated from the complex was performed in negative ionization mode using a denaturing sheath liquid, allowing the determination of its molecular mass and sulfation features. This FACE-ESIMS strategy opens the way to ligand fishing experiments performed on heterogeneous carbohydrate mixtures and subsequent characterization of specifically bound carbohydrates.Keywords
This publication has 28 references indexed in Scilit:
- Recent advances in the application of capillary electrophoresis with mass spectrometric detectionElectrophoresis, 2006
- SPR Studies of Carbohydrate–Protein Interactions: Signal Enhancement of Low‐Molecular‐Mass Analytes by Organoplatinum(II)‐LabelingChemBioChem, 2005
- Mass spectrometry of oligosaccharidesMass Spectrometry Reviews, 2004
- Liquid Chromatography/Mass Spectrometry Sequencing Approach for Highly Sulfated Heparin-derived OligosaccharidesJournal of Biological Chemistry, 2004
- Effects of nebulizing and drying gas flow on capillary electrophoresis/mass spectrometryRapid Communications in Mass Spectrometry, 2002
- In AC Research: In AC Research2001
- Defining the structure and stability of macromolecular assemblies in solution: the re-emergence of analytical ultracentrifugation as a practical toolStructure, 1996
- Effects of Anions on the Positive Ion Electrospray Ionization Mass Spectra of Peptides and ProteinsAnalytical Chemistry, 1994
- Heat-induced conformational changes in proteins studied by electrospray ionization mass spectrometryAnalytical Chemistry, 1993
- Irreversible inhibition of 3-dehydroquinate synthaseJournal of the American Chemical Society, 1991