Determination of hydrogen peroxide by utilizing a cobalt( II )hexacyanoferrate‐modified glassy carbon electrode as a chemical sensor
Authors:
- 1 March 1997
- journal article
- feature aricle
- Published by Wiley in Electroanalysis
- Vol. 9 (4) , 340-344
Abstract
A mixed‐valence cluster of cobalt(II)hexacyanoferrate possesses an electron transfer property and is suitable for the development of an effective hydrogen peroxide detection scheme. The characteristics of cobalt(II)hexacyanoferrate have been studied using both elemental analysis and infrared spectra, confirming the structure is Co [Fe II (CN) 6 ]. The cobalt(II)hexacyanoferrate‐modified electrode exhibits a rapid response ( t 95% ‐ 6.5 s) to the injection of 5.0 × 10 −5 M hydrogen peroxide. The linearity of the response is up to 1.1 × 10 −3 M (correlation coefficients is 0.999). The sensitivity of this modified electrode is 11.8 μA/mM‐mm 2 . The detection limit of cobalt(II)hexacyanoferrate‐modified electrode to hydrogen peroxide is 6.25 × 10 −8 M. The current chemical sensor modified with Co [Fe II (CN) 6 ] has better sensitivity than previous ones. The modified glassy carbon electrode shows no interference from ascorbic acid, uric acid, acetaminophen, 1,4‐dihydroxyquinone, dopamine at the 2.0 × 10 −4 M level and polyamines at 5.0 × 10 −5 M level.Keywords
This publication has 25 references indexed in Scilit:
- Regenerated silk fibroin membrane as immobilization matrix for peroxidase and fabrication of a sensor for hydrogen peroxide utilizing methylene blue as electron shuttleAnalytica Chimica Acta, 1995
- A reagentless amperometric biosensor for hydrogen peroxide determination based on asparagus tissue and ferrocene mediationAnalytica Chimica Acta, 1995
- Remarkably selective metallized-carbon amperometric biosensorsAnalytica Chimica Acta, 1995
- Internal enzyme fiber-optic biosensors for hydrogen peroxide and glucoseAnalytica Chimica Acta, 1995
- Enzyme Microelectrode Array Strips for Glucose and LactateAnalytical Chemistry, 1994
- Amperometric internal enzyme gas-sensing probe for hydrogen peroxideAnalytica Chimica Acta, 1993
- Pineapple‐tissue based bioelectrode for the determination of hydrogen peroxideElectroanalysis, 1990
- Grape tissue-based electrochemical sensor for the determination of hydrogen peroxideAnalytica Chimica Acta, 1990
- Exploitation of reversed micelles as a medium in analytical chemiluminescence measurements with application to the determination of hydrogen peroxide using luminolAnalytical Chemistry, 1987
- Infrared spectra of the Prussian blue analogsJournal of Inorganic and Nuclear Chemistry, 1974