Frequency of Common Bile Duct Motion Artifacts Caused by Inferior Vena Cava Pulsation on Magnetic Resonance Cholangiopancreatography
Open Access
- 1 January 2008
- journal article
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 7 (1) , 31-36
Abstract
Purpose: We assessed the frequency of common bile duct (CBD) motion artifacts caused by inferior vena cava (IVC) pulsation on magnetic resonance cholangiopancreatography (MRCP). Methods: We retrospectively evaluated CBD motion artifacts in 4 MRCP sequences from each of 115 consecutive patients. Results: We observed 37 (32.2%) ghost artifacts at the ventral and dorsal aspects of the CBD on transaxial, half-Fourier acquisition single-shot turbo spin-echo (HASTE-ax) images; no such artifacts were observed on transaxial T2-weighted turbo spin-echo images. In 10 patients, we observed 9 (7.8%) pseudo-defects of the CBD on 3-dimensional T2-weighted turbo spin-echo with navigator-triggered prospective acquisition correction technique MRCP and 6 (5.2%) pseudo-defects on single-shot rapid acquisition with relaxation enhancement MRCP. Pseudo-defects were significantly more frequent in patients with ghost artifacts than without (9 of 37 [24.3%] versus one of 78 [1.3%]; P<0.01, McNemar test). Conclusion: Although uncommon, pseudo-defects of the CBD caused by IVC pulsation are observed on MRCP. MRCP interpretation that includes comparison with HASTE-ax images can diminish the potential misinterpretation of such CBD motion artifact as bile duct tumor or biliary stone.Keywords
This publication has 11 references indexed in Scilit:
- Magnetic resonance cholangiopancreatography using a free-breathing T2-weighted turbo spin-echo sequence with navigator-triggered prospective acquisition correctionMagnetic Resonance Imaging, 2005
- Magnetic resonance imaging of the upper abdomen using a free‐breathing T2‐weighted turbo spin echo sequence with navigator triggered prospective acquisition correctionJournal of Magnetic Resonance Imaging, 2005
- Fast and ultrafast non-echo-planar MR imaging techniquesEuropean Radiology, 2002
- MR Cholangiopancreatography of Bile and Pancreatic Duct Abnormalities with Emphasis on the Single-Shot Fast Spin-Echo TechniqueRadioGraphics, 2000
- Pseudo-obstruction of the Extrahepatic Bile Duct Due to Artifact from Arterial Pulsatile Compression: A Diagnostic Pitfall of MR CholangiopancreatographyRadiology, 2000
- Diagnostic Pitfalls of MR Cholangiopancreatography in the Evaluation of the Biliary Tract and GallbladderRadioGraphics, 1999
- MR cholangiopancreatography of pancreaticobiliary diseases: comparing single-shot RARE and multislice HASTE sequences.American Journal of Roentgenology, 1998
- Ghost artifact on gradient-echo imaging: a potential pitfall in hepatic imaging.American Journal of Roentgenology, 1990
- Echocardiographic assessment of the inferior vena cava wall motion for studies of right heart dynamics and functionClinical Cardiology, 1984
- Reat-time inferior vena caval ultrasonography: normal and abnormal findings and its use in assessing right-heart function.Circulation, 1981