Cumulative Neutral Loss Model for Fragment Deconvolution in Electrospray Ionization High-Resolution Mass Spectrometry Data
Open Access
- 7 August 2023
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (33) , 12247-12255
Abstract
Clean high-resolution mass spectra (HRMS) are essential to a successful structural elucidation of an unknown feature during nontarget analysis (NTA) workflows. This is a crucial step, particularly for the spectra generated during data-independent acquisition or during direct infusion experiments. The most commonly available tools only take advantage of the time domain for spectral cleanup. Here, we present an algorithm that combines the time domain and mass domain information to perform spectral deconvolution. The algorithm employs a probability-based cumulative neutral loss (CNL) model for fragment deconvolution. The optimized model, with a mass tolerance of 0.005 Da and a scoreCNL threshold of 0.00, was able to achieve a true positive rate (TPr) of 95.0%, a false discovery rate (FDr) of 20.6%, and a reduction rate of 35.4%. Additionally, the CNL model was extensively tested on real samples containing predominantly pesticides at different concentration levels and with matrix effects. Overall, the model was able to obtain a TPr above 88.8% with FD rates between 33 and 79% and reduction rates between 9 and 45%. Finally, the CNL model was compared with the retention time difference method and peak shape correlation analysis, showing that a combination of correlation analysis and the CNL model was the most effective for fragment deconvolution, obtaining a TPr of 84.7%, an FDr of 54.4%, and a reduction rate of 51.0%.Keywords
All Related Versions
Funding Information
- Agilent Technologies (4523)
This publication has 36 references indexed in Scilit:
- Automatic recalibration and processing of tandem mass spectra using formula annotationJournal of Mass Spectrometry, 2012
- A cross-platform toolkit for mass spectrometry and proteomicsNature Biotechnology, 2012
- CAMERA: An Integrated Strategy for Compound Spectra Extraction and Annotation of Liquid Chromatography/Mass Spectrometry Data SetsAnalytical Chemistry, 2011
- AStream: an R package for annotating LC/MS metabolomic dataBioinformatics, 2011
- MZmine 2: Modular framework for processing, visualizing, and analyzing mass spectrometry-based molecular profile dataBMC Bioinformatics, 2010
- A Statistically Rigorous Test for the Identification of Parent−Fragment Pairs in LC-MS DatasetsAnalytical Chemistry, 2010
- Highly sensitive feature detection for high resolution LC/MSBMC Bioinformatics, 2008
- Towards de novo identification of metabolites by analyzing tandem mass spectraBioinformatics, 2008
- Mass spectrometry for the identification of the discriminating signals from metabolomics: Current status and future trendsJournal of Chromatography B, 2008
- XCMS: Processing Mass Spectrometry Data for Metabolite Profiling Using Nonlinear Peak Alignment, Matching, and IdentificationAnalytical Chemistry, 2006