Does implantation of larger bioprosthetic pulmonary valves in young patients guarantee durability in adults? Durability analysis of stented bioprosthetic valves in the pulmonary position in patients with Tetralogy of Fallot
Authors:
Open Access
- 30 August 2015
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 49 (4) , 1207-1212
Abstract
In a previous study, we identified factors affecting the durability of bioprosthetic valves in the pulmonary position following total repair of Tetralogy of Fallot (TOF). In this study, we aimed to identify factors affecting the durability of the bioprosthetic valve with regard to patient age and implanted valve size in order to guide valve choice in adolescent patients. We enrolled and analysed 108 cases of pulmonary valve replacement (PVR) with stented bioprosthetic valves in TOF patients between January 1998 and February 2014. Valvular dysfunction was defined as at least a moderate amount of pulmonary regurgitation or a peak pressure gradient of ≥40 mmHg on the most recent echocardiography. We analysed the effect of patient age and valve size on the durability of the bioprosthetic valve in the pulmonary position. There were 2 early deaths; no late deaths were observed. The follow-up duration was 92.8 ± 44.5 months. The mean age at PVR was 19.3 ± 9.1 years. The mean valve size was 24.7 ± 1.8 mm. Whereas patients ≥20 years old showed no valvular dysfunction (i.e. 100% freedom from valvular dysfunction at 10 and 14 years), patients who were adolescents and children (z -score of valve size (68.2% at 10 years and 24.7% at 14 years). Although a larger valve with a z -score of ≥2 was implanted, patients z -score of valve size. However, patients who were children and adolescents did not show optimal durability of the bioprosthetic valve, irrespective of the z -score of valve size.Keywords
This publication has 19 references indexed in Scilit:
- Twenty-year durability of the aortic Hancock II bioprosthesis in young patients: is it durable enough?†European Journal of Cardio-Thoracic Surgery, 2014
- Surgical pulmonary valve insertionCardiology in the Young, 2013
- Surgical pulmonary valve insertion – when, how, and whyCardiology in the Young, 2012
- Outcomes of Pulmonary Valve Replacement in 170 Patients With Chronic Pulmonary Regurgitation After Relief of Right Ventricular Outflow Tract ObstructionJACC, 2012
- Bicuspid pulmonary valve implantation using polytetrafluoroethylene membrane: early results and assessment of the valve function by magnetic resonance imagingEuropean Journal of Cardio-Thoracic Surgery, 2012
- Durability of bioprosthetic valves in the pulmonary position: Long-term follow-up of 181 implants in patients with congenital heart diseaseThe Journal of Thoracic and Cardiovascular Surgery, 2011
- Mid-term Results of the Hancock II Valve and Carpentier-Edward Perimount Valve in the Pulmonary Portion in Congenital Heart DiseaseHeart, Lung and Circulation, 2010
- Durability of pericardial versus porcine aortic valvesJACC, 2004
- Late pulmonary valve replacement after repair of tetralogy of FallotThe Journal of Thoracic and Cardiovascular Surgery, 2001
- Independent factors associated with longevity of prosthetic pulmonary valves and valved conduitsThe Journal of Thoracic and Cardiovascular Surgery, 2000