Treatment of Orbital Fractures
Authors:
- Daniel NowinskiDNDaniel Nowinski
- Elias MessoEMElias Messo
- Anders HedlundAHAnders Hedlund
- 1 July 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 21 (4) , 1033-1037
Abstract
Reconstruction of the fractured orbit serves to prevent functional and aesthetic posttraumatic sequels. In 2004, the surgical protocol at our unit was modified with respect to techniques for surgical access, types, and materials for reconstruction. The modifications were as follows: (a) introduction of medial orbital wall reconstructions through a bicoronal approach, (b) transconjunctival approach instead of the subciliary approach, and (c) porous polyethylene or porous polyethylene-titanium instead of autologous bone grafts. To evaluate the different surgical techniques and materials used, orbital reconstructions performed at our unit from 2000 to 2007 were retrospectively studied. In total, 177 primary or first-time secondary reconstructions were performed in 176 patients. The overall rate of early complications requiring medical or surgical intervention was 6.4%, and the reoperation rate was 3.4%. There were no statistically significant differences in the frequency of cicatricial eyelid complications between the subciliary and the transconjunctival approaches. There was a reduction in operative time with the use of implants compared with the use of bone. The overall rate of infections was 2%; however, there were no infections in the group treated with implants. Seven patients had secondary surgery for persistent enophthalmos, 4 of them due to defects in the medial orbital wall that had not been corrected at the time of primary reconstruction of the orbital floor. In conclusion, porous polyethylene/porous polyethylene-titanium is a safe material for orbital reconstructions. Reconstruction of the medial orbital wall is important to prevent posttraumatic enophthalmos, particularly in combined medial wall-orbital floor fractures.Keywords
This publication has 16 references indexed in Scilit:
- A comparative study of different approaches in the treatment of orbital trauma: an experience based on 274 casesOral and Maxillofacial Surgery, 2009
- Combined Transconjunctival and Transcaruncular Approach for Repair of Large Medial Orbital Wall FracturesArchives of Ophthalmology (1950), 2009
- An Examination of Posttraumatic, Postsurgical Orbital Deformities: Conclusions Drawn for Improvement of Primary TreatmentPlastic and Reconstructive Surgery, 2008
- Use of Porous Polyethylene With Embedded Titanium in Orbital Reconstruction: A Review of 106 PatientsOphthalmic Plastic & Reconstructive Surgery, 2007
- Semiautomatic Procedure for Individual Preforming of Titanium Meshes for Orbital FracturesPlastic and Reconstructive Surgery, 2007
- Reconstruction of Internal Orbital Wall Fracture with Iliac Crest Free Bone Graft: Clinical, Computed Tomography, and Magnetic Resonance Imaging Follow-Up StudyPlastic and Reconstructive Surgery, 2006
- Primary and Secondary Orbit Surgery: The Transconjunctival ApproachPlastic and Reconstructive Surgery, 1999
- The Natural History of Alloplastic Implants in Orbital Floor ReconstructionJournal of Craniofacial Surgery, 1994
- Use of Medpor Porous Polyethylene Implants in 140 Patients with Facial FracturesJournal of Craniofacial Surgery, 1993
- A Randomized Comparison of Four Incisions for Orbital FracturesPlastic and Reconstructive Surgery, 1981